![](/images/new-backgrounds/1007564/756411x1.webp)
2. SPECIFICATIONS
(1) Unit Specifications
| MODEL No. |
| Indoor Unit |
|
| XS4232 |
|
| |||
|
|
| Outdoor Unit |
|
| C4232 |
|
| |||
| POWER SOURCE |
|
|
|
| 230 - 208 V / 1 Phase / 60 Hz |
| ||||
| PERFORMANCE |
|
|
|
|
| Cooling |
|
| ||
| Capacity |
|
| BTU / h | 42,000 |
|
| 40,500 |
| ||
|
|
|
|
|
| kW | 12.32 |
|
| 11.88 |
|
| Air circulation (Hi) |
|
| cu.ft. / min. | 980 |
|
| 880 |
| ||
| Moisture removal (High) |
|
| Pints / h | 14.6 |
|
| 14.8 |
| ||
| ELECTRICAL RATINGS |
|
|
|
|
|
|
|
|
| |
| Voltage rating |
|
|
| VAC | 230 |
|
| 208 |
| |
| Available voltage range |
|
|
| VAC |
| 187 - 253 |
|
| ||
| Running amperes* |
|
|
| A | 20.8 |
|
| 21.1 |
| |
| Max. running amperes** |
|
|
| A | 24.1 |
|
| 25.3 |
| |
| Power input |
|
|
| W | 4,230 |
|
| 4,120 |
| |
| Power factor |
|
|
| % | 88 |
|
| 94 |
| |
| S.E.E.R |
|
| BTU / Wh | 10.2 |
|
| 10.3 |
| ||
| Max. starting amperes |
|
|
| A | 134 |
|
| 134 |
| |
| Maximum fuse size |
|
|
| A |
| 50 |
|
| ||
| FEATURES |
|
|
|
|
|
|
|
|
| |
| Controls |
|
|
|
|
| Microprocessor |
| |||
| Timer |
|
|
|
| ON / OFF |
| ||||
| Fan speed Indoor / Outdoor |
|
|
|
| 3 and Automatic control / 2 (Auto) |
| ||||
| Air deflection | Horizontal / Vertical |
|
|
| ||||||
| Air filter |
|
|
|
| Washable, easy access, long life (2,500 hr) | |||||
| Remote controller (Accessory) |
|
|
|
|
| RCS - 5PS4U |
| |||
| Refrigerant control |
|
|
|
|
| Capillary tube |
| |||
| Refrigerant tubing connections |
|
|
|
|
| Flare type |
|
| ||
| Drain pump / Drain pipe trade size |
|
|
| Max. head | ||||||
| Compressor |
|
|
|
|
| Scroll |
|
| ||
| Operation sound |
| Indoor - Hi / Me / Lo | dB - A |
| 43 / 40 / 36 |
|
| |||
|
|
| Outdoor - Hi |
| dB - A |
| 56 |
|
| ||
| REFRIGERANT TUBING |
|
|
|
|
|
|
|
|
| |
| Limit of tubing length |
|
| ft. | (m) |
| 165 (50) |
|
| ||
| Limit of tubing length at shipment |
| ft. | (m) |
| 50 (15) |
|
| |||
| Limit of elevation difference |
|
| ft. | (m) | Outdoor unit is higher than indoor unit: 165 (50) | |||||
| between the two units |
|
|
|
| Outdoor unit is lower than indoor unit: 100 (30) | |||||
| Refrigerant tube |
| Narrow tube |
| in. (mm) |
| 3 / 8 (9.52) |
|
| ||
| outer diameter |
| Wide tube |
| in. (mm) |
| 3 / 4 (19.05) |
|
| ||
| Refrigerant amount at shipment |
| lbs. (kg) |
| R22 : 9.7 (4.4) |
| |||||
| DIMENSIONS & WEIGHT |
|
|
|
| Indoor unit |
| Outdoor unit | |||
| Unit dimensions |
| Height |
| in. (mm) | (280) |
| (1,235) | |||
|
|
| Width |
| in. (mm) | (1,050) |
| 37 | (940) | ||
|
|
| Depth |
| in. (mm) | (760) |
| (340) | |||
| Net weight |
|
|
| lbs. (kg) | 60 | (27) |
| 205 | (93) | |
| Indoor grille dimensions |
| Height |
| in. (mm) | (78) |
| – |
| ||
|
|
| Width |
| in. (mm) | (1,150) |
| – |
| ||
|
|
| Depth |
| in. (mm) | (860) |
| – |
| ||
| Net weight |
|
|
| lbs. (kg) | 15 | (7) |
| – |
| |
| Indoor Unit |
| Height |
| in. (mm) | (316) |
| (1,326) | |||
| Package dimensions |
| Width |
| in. (mm) | (1,114) |
| 40 | (1,016) | ||
|
|
| Depth |
| in. (mm) | (833) |
| (416) | |||
| Shipping weight |
|
|
| lbs. (kg) | 71 | (32) |
| 229 | (104) | |
| Shipping volume |
| cu. ft. (m3) | 10.3 | (0.293) |
| 19.8 | (0.56) | |||
| Indoor grille |
| Height |
| in. (mm) | (104) |
| – |
| ||
| Package dimensions |
| Width |
| in. (mm) | (1,257) |
| – |
| ||
|
|
| Depth |
| in. (mm) | (999) |
| – |
| ||
| Shipping weight |
|
|
| lbs. (kg) | 29 | (10) |
| – |
| |
| Shipping volume |
| cu. ft. (m3) | 4.6 | (0.131) |
| – |
|
DATA SUBJECT TO CHANGE WITHOUT NOTICE
Cooling :
Rating conditions (*) : Indoor air temperature 80 °F DB / 67 °F WB, Outdoor air temperature 95 °F DB / 75 °F WB
Full load conditions (**) : Indoor air temperature 80 °F DB / 67 °F WB, Outdoor air temperature 115 °F DB
SM830078
– 6 –