Preparing for use
The operation display shows information necessary for operation, such as the date, time and video quality. The operation display can be hidden.
12 3 4 5 6 7 8
02
F9
Changing the position of the operation display
Whenever the EXIT/OSD button is pressed, the position of the operation display changes.
EXIT/OSD
(Hidden)
02
1Date display
2Time display
00:00:00: Do not forget to set the time using the menu settings when turning the power on for the first time.
3Operation symbols
The operation symbols are displayed during recording and control operations.
REC: Recording |
|
|
|
|
| : | |||
EXT: External timer |
|
|
|
|
| : | |||
|
|
| recording |
|
|
|
|
| : Slow playback |
|
|
|
|
| |||||
|
|
| : Reverse playback |
|
|
|
|
| : Reverse slow playback |
|
|
|
|
|
|
|
| ||
|
|
| : Still |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
: Playback (including simultaneous recording and playback)
4Remaining recording area (P46)
It is displayed only during normal and alarm recording.
1% ~ 100%:
If overwrite is not permitted on the hard disk, it displays the remaining area as a percentage.
REPEAT:
Repeatedly overwrites the video on the hard disk.
5Image quality display
The image quality display indicates the quality of the video recorded on the hard disk.
BA (Basic): Rough image quality, approx. 15kB
NO (Normal): Standard image quality, approx. 22kB
EN (Enhanced): Enhanced image quality, approx. 30kB
FI (Fine): Fine image quality, approx. 42kB
SF (Super Fine): Super fine image quality, approx. 50kB
6Audio recording indicator (P49: 2 AUDIO RECORDING)
Displayed when audio recording is performed.
7Recording type
•ALARM: Alarm playback or standby is in progress
•ALARM (Blinking): Alarm recording is in progress
•PRE:
•ARCHIV: Archive playback is in progress
8Alarm total
The alarm total indicates the total number of alarms.
9Camera title
•01~06:
First it displays the camera number. The camera number can be replaced with a name such as the camera's location.
•VIDEO LOSS:
The display alternates between this message and the camera number when the camera video is lost. When the operations display of the monitor is hidden the message blinks in the same position.
•NO VIDEO:
It is displayed in place of the camera number if there is no video signal connected to the video input terminal.
FAlarm type
•EA: The display alternates between this message and the camera title when an external alarm signal is detected.
•SA: The display alternates between this message and the camera title when a motion sensor alarm signal is detected.
•ES: The display alternates between this message and the camera title when an external alarm signal and a motion sensor signal are detected.
English