e00_VDH_M814.book Page 66 Thursday, October 28, 2004 9:59 AM

APPENDIX

1. CONTROL TERMINAL SPECIFICATIONS

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19

Terminal

Name

Signal

Function

No.

 

 

 

 

 

 

 

1

RS-485A

RS-485

To RS-485 terminal signal

A*1

 

 

 

2

RS-485B

RS-485

To RS-485 terminal signal

B*1

 

 

 

3

C

 

Common

 

 

 

 

4

REMOTE

Resistance ladder

Remote Control terminal

connection

 

 

 

 

 

 

 

5

C

 

Common

 

 

 

 

6

CLOCK ADJ IN

Normal open,

Input for clock setting

 

 

Low level active

 

 

CLOCK ADJ

Normal resistance

 

7

5V DC/57k,

Output for clock setting

OUT

 

Low level active

 

 

 

 

 

 

 

 

8

C

 

Common

 

 

 

 

 

 

 

Input terminal used when

9

SERIES REC

Normal open,

recording with multiple

IN

Low level active

digital video recorders

 

 

 

 

connected.

 

 

 

 

 

NON REC

Normal resistance

Output terminal used

 

when recording with

10

OUT/SERIES

5V DC/57k,

multiple digital video

 

REC OUT

Low level active

 

recorders connected.*2

 

 

 

11

ALARM IN 1

Normal open,

Alarm input for channel 1

Low level active

 

 

 

 

 

 

 

12

ALARM IN 2

Normal open,

Alarm input for channel 2

Low level active

 

 

 

 

 

 

 

13

ALARM IN 3

Normal open,

Alarm input for channel 3

Low level active

 

 

 

 

 

 

 

14

ALARM IN 4

Normal open,

Alarm input for channel 4

Low level active

 

 

 

 

 

 

 

15

ALARM

Normal open,

Alarm reset input

RESET

Low level active

 

 

 

 

 

 

 

 

Normal resistance

 

16

ALARM OUT

5V DC/57k,

ALARM OUT

 

 

Low level active

 

 

 

 

 

17

C

 

Common

 

 

 

 

 

WARNING

Open collector

 

18

(500 mA),

Warning output*3

OUT

 

Low level active

 

 

 

 

 

 

 

 

 

DISK FULL

Open collector

Recording area full

19

(500 mA),

OUT

warning

 

Low level active

 

 

 

 

 

 

 

*1

Used for twisted-pair cable connection.

*2

Outputs SERIES REC OUT when OVER WRITE in REC MODE SET is

 

“OFF”, and SERIES REC is “-1M”, “-2M”, or “-3M”. Outputs NON REC

 

OUT when SERIES REC is “OFF”.

*3

The following warnings are output:

 

z Hard disk drive error z Fan error z Recording error

 

z No input signal when VIDEO LOSS is ON.

Connecting cables to the control terminals

Cable

Flat-blade screwdriver

(1)Push in the lock pin with a flat-blade screwdriver.

(2)Insert the cable.

(3)Pull out the lock pin with a flat-blade screwdriver. The cable is now secured in place.

System controller connections

The connections for a system controller are shown below. Insert a twisted-pair cable (sold separately) into the RS-485A, RS-485B and C (ground) terminals on the rear panel. Connect the RS-485A and RS-485B output to signal A and signal B respectively of the system controller.

RS-485

A B C

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19

Twisted-pair cable

To signal B

 

To signal A

Ground

RS-485

 

terminal

System controller (sold separately)

zTwisted-pair cable

Reduces signal interference caused by noise from other cables.

zFor information about the system controller, contact your local dealer.

APPENDIX

66