NOTE: Be sure to reset correct lamp number otherwise LAMP REPLACE indicator continues lighting.
4 Another confirmation dialog box appears and select [Yes] to reset Lamp Replace Counter.
Do not reset Lamp Replace Counter except after Projection lamp is replaced.
LAMP REPLACE COUNTER
Be sure to reset Lamp Counter when Lamp Assembly is replaced. When Lamp Replace Counter is reset, LAMP REPLACE indicator stops lighting.
1 Turn projector on, press MENU button and ON-SCREEN MENU will appear. Press POINT LEFT/RIGHT button(s) to move a red frame pointer to SETTING Menu icon.

APPENDIX

ORDER REPLACEMENT LAMP

Replacement Lamp can be ordered through your dealer. When ordering a Projection Lamp, give the following information to the dealer.

Model No. of your projector

:

PLC-XF46N/E

Replacement Lamp Type No.

:

POA-LMP100

 

 

 

(Service Parts No. 610 327 4928)

 

 

 

 

 

 

 

 

2

Press POINT DOWN button to move a red frame pointer to

 

 

 

 

“Lamp counter reset” and then press SELECT button.

 

 

 

3

Move arrow to replaced lamp number (Lamp 1, Lamp 2, Lamp 3

 

 

Move pointer to Lamp counter reset and then

or Lamp 4) and then press SELECT button. Message "Lamp

 

 

 

 

press SELECT button. Move arrow to

1

3

 

replace counter Reset?" is displayed. Move pointer to [Yes] and

 

 

replaced lamp number (Lamp 1, Lamp

 

2

4

 

then press SELECT button.

 

 

2, Lamp 3 or Lamp 4) and then press

 

 

 

SELECT button.

Message "Lamp replace counter Reset?" is displayed. Move pointer to [Yes] and then press SELECT button.

Select [Yes] to activate it.

45