Maintenance and Cleaning
Lamp Replacement
When the life of the projection lamps of this projector draw to an | Top Control |
end, the LAMP 1 and 2 REPLACE indicators light orange. If one of |
|
these indicators lights orange, replace the lamp with a new one |
|
promptly. |
|
CAUTION
For continued safety, replace with a lamp of the same type. Do not drop a lamp or touch a glass bulb! The glass can shatter and may cause injury.
Allow a projector to cool, for at least 45 minutes before you open the Lamp cover. The inside of the projector can become very hot.
LAMP 1 REPLACE | LAMP 2 REPLACE |
indicator | indicator |
These indicators light orange when the life of the projection lamps draw to an end.
Follow these steps to replace the lamp.
1 | Turn off the projector and disconnect the AC plug. Allow the |
| projector to cool for at least 45 minutes. |
2 | Loosen each screw on the lamp covers with a screwdriver, |
| and remove the lamp covers. |
3 | Loosen two (2) screws of each lamp with a screwdriver and |
| pull out one lamp and another with grasping the handle. |
4 | Replace each lamp with a new one and tighten the two (2) |
| screws back into the positions. Make sure that the lamp is |
| set properly. Replace the lamp covers and tighten the |
| screws. |
5 | Connect the AC power cord to the projector and turn on the |
| projector. |
6 | Reset the Lamp time. |
| See Lamp on page 57. |
CAUTION :
DO NOT OPERATE A PROJECTOR WHILE ANY OF LAMPS IS REMOVED. IT MAY RESULT IN MALFUNCTIONS, FIRE HAZARD, OR OTHER ACCIDENTS.
NOTES ON LAMP REPLACEMENT:
TO MAINTAIN QUALITY OF PICTURE (BETTER BALANCE OF COLOR AND BRIGHTNESS IN THE ENTIRE SCREEN), WE RECOMMEND REPLACING ALL 2 LAMPS AT A TIME.
Lamp covers
Screws
(Unremovable)
Lamp 1 | Lamp 2 |
Handle
ScrewsHandle
62