25
Indoor Unit : SAP-KRV123EH
|
|
|
|
|
|
|
|
|
|
| TERMINAL BASE | |||
EVAPORATOR |
|
|
|
|
|
|
| BRN |
| 1 |
|
| ||
|
|
|
| GRY |
|
|
| 2 |
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
| GRY |
| GRN/YEL |
|
|
| |
GRN/YEL |
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| RED | 4 |
|
| ||
|
|
|
|
|
|
|
|
| BRN | L |
| POWER SUPPLY | ||
|
|
|
|
|
|
|
|
| N |
| ||||
|
|
|
|
|
|
|
|
| BLU |
| ||||
|
|
|
|
|
|
|
|
| GRN/YEL |
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
| EARTH |
|
|
|
|
| 4 | AC IN | SI1 | SI |
|
|
|
|
|
|
|
|
|
|
| 3 | POWER | 1 | 1 | RED | 1 | 1 |
| ||
|
|
|
|
|
|
| ||||||||
|
|
|
|
| RY01 | RELAY |
| 2 | 2 | WHT | 2 2 | ASSY | ||
|
|
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
| 3 | 3 | WHT | 3 3 | |||
|
| RED |
|
|
|
|
|
| ||||||
1 | 1 | 1 | 1 |
|
|
|
| 4 | 4 | WHT | 4 | 4 | ||
|
|
| LAMP | LAMP | ||||||||||
2 | 2 | PNK | 2 | 2 |
|
|
| 5 | 5 | WHT | 5 | 5 | ||
FLAP 3 | 3 | BLU | 3 | 3 | FLAP |
| 9P(WHT) | 6 | 6 | WHT | 6 | 6 | ||
4 | 4 | BRN | 4 | 4 | 5P(WHT) |
|
| 7 | 7 | WHT | 7 | 7 | IND | |
5 | 5 | YEL | 5 | 5 |
|
|
|
| 8 | 8 | WHT | 8 | 8 | |
FLAP MOTOR |
|
|
|
|
|
| 9 | 9 | WHT | 9 9 |
| |||
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
| CONTROLLER |
|
|
| THERMISTOR | |||||
FAN MOTOR |
|
|
|
|
|
|
|
|
| |||||
1 | 1 | FAN |
|
|
|
|
|
| (ROOM) | |||||
|
| (RED) |
|
|
| 1 | 1 | BLK |
|
|
| |||
|
| PNK | 3 | 3 | 5P(WHT) |
|
|
|
|
| ||||
|
| BRN | 5 | 5 |
| ROOM/COIL | 2 | 2 | BLK |
|
|
| ||
|
| WHT |
|
|
| 3 | 3 | BLK(ORG) |
|
| ||||
FM |
|
|
|
|
| 4P(WHT) | 4 | 4 | BLK(ORG) |
|
| |||
| RED | 1 | 1 |
|
|
|
| |||||||
|
| HALL IC |
|
|
|
|
| THERMISTOR | ||||||
|
| BLK | 2 | 2 |
|
|
|
|
| |||||
|
| YEL | 3 | 3 | 3P(WHT) |
|
|
|
|
| (COIL) | |||
GRN/YEL |
|
|
|
|
|
| HA | 1 |
|
|
|
|
| |
|
|
|
|
|
|
| 2 |
|
|
|
|
| ||
|
| BLU |
|
| FMC1 | 3 |
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
| ||||
FAN MOTOR |
|
|
|
|
| 4P(WHT) | 4 |
|
|
|
|
| ||
CAPACITOR |
| PNK |
|
| FMC2 |
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
Outdoor Unit : SAP-CRV123EH
1 |
| BLK |
|
|
|
|
|
|
|
| REACTANCE | MAGNETIC COIL |
|
|
|
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
2 |
| WHT |
|
|
|
|
|
|
|
|
|
|
|
|
|
| MV |
|
|
|
|
|
|
| |
|
| GRN/YEL |
|
|
|
|
|
|
|
|
|
|
|
| 1 | 2 | 3 | 4 | 5 | 6 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
4 |
| RED |
|
|
|
|
|
|
|
|
|
|
|
| 1 | 2 | 3 | 4 | 5 | 6 |
|
|
|
|
|
TERMINAL | FERRITE CORE |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
BASE |
|
|
|
|
| ORG | BLK |
|
| WHT |
|
| WHT | ORG RED GRY WHT YEL BLK |
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 1 | 2 | 3 | 4 | 5 | 6 |
|
|
|
|
|
|
| W W W |
|
|
|
| W W W W |
| W |
|
| W | 1 2 3 4 5 6 |
|
|
|
|
| |||||||
|
| S1 IN2 IN1 |
|
| OUT+ | OUT– | IN– IN+ | L1 |
|
| L2 |
|
| MV |
|
|
|
|
|
|
| ||||
1 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| (BLK) |
|
| W | W | BLU |
|
| |
|
|
|
|
| CONTROLLER |
|
|
|
|
|
|
|
|
|
| V | W | WHT |
|
| |||||
2 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| VL3P CONNECTOR | ||||||||
3 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| U | W | RED |
| |
|
|
|
| (WHT) |
|
|
|
|
| (WHT) |
|
| (WHT) |
| |||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||
| E |
|
| DCFM |
|
| RV2 RV1 | OUTDOOR |
| COIL/COMP |
|
| 1 2 3 | ||||||||||||
| W | 1 2 3 4 5 6 7 | W W |
| 1 2 |
|
| 1 2 3 4 |
|
|
| 1 2 3 | |||||||||||||
|
| 1 | 2 | 3 | 4 | 5 | 6 | 7 |
|
|
|
| 1 | 2 |
|
| 1 | 2 | 3 | 4 |
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| GRN/YEL | WHT |
|
| BLK RED BLU | YEL | BLU BLU | YL2P CONNECTOR |
| BLK BLK |
|
| YEL YEL BLK BLK |
|
|
|
| FERRITE CORE | |||||||
|
|
|
|
|
|
| 2 | 1 | OUTDOOR | COIL THERMISTOR | THERMISTOR |
|
|
| |||||||||||
|
|
|
|
|
|
| 2 | 1 |
| (PNK) RED WHT BLU | |||||||||||||||
| GRN/YEL |
|
|
| FM |
|
|
| |||||||||||||||||
|
|
|
|
|
|
| BLU BLU |
| |||||||||||||||||
|
|
|
|
|
|
| THERMISTOR | COMPRESSOR |
| ||||||||||||||||
|
|
|
| FAN MOTOR |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| R |
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| / |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| S/U | V | C/W |
|
|
|
|
|
|
|
|
| RV |
|
|
|
|
|
|
|
|
|
|
| GRN/YEL | CM |
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| COMPRESSOR | |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| MOTOR |
| ||||
|
| Meaning of Abbreviations |
|
|
|
|
|
|
|
|
|
| |||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ABBREV. | MEANING |
|
|
|
1 | BLK | BLACK |
|
|
|
2 | BLU | BLUE |
|
|
|
3 | BRN | BROWN |
|
|
|
4 | GRN/YEL | GREEN/YELLOW |
|
|
|
5 | G R Y | GREY |
|
|
|
6 | ORG | ORANGE |
|
|
|
7 | PNK | PINK |
|
|
|
8 | RED | RED |
|
|
|
9 | V LT | VIOLET |
|
|
|
10 | WHT | W HITE |
|
|
|
11 | YEL | YELLOW |
|
|
|
Outdoor Unit | Indoor Unit |
To avoid electrical shock hazard, be sure to WARNING disconnect power before checking, servicing and/or cleaning any electrical parts.