7. INSTALLATION INSTRUCTIONS

7. INSTALLATION INSTRUCTIONS

7-1. Installation Site Selection

7-1-1. Indoor Unit

WARNING

AVOID:

To prevent abnormal heat generation and the possibility of fire, do not place obstacles, enclosures and grilles in front of or surrounding the air con- ditioner in a way that may block air flow.

5 cm

15 cm min.

5 cm

 

min.

 

min.

 

Front View

 

direct sunlight.

nearby heat sources that may affect performance of the unit.

areas where leakage of flammable gas may be expected.

places where large amounts of oil mist exist.

DO:

select an appropriate position from which every cor-

ner of the room can be uniformly cooled. (High on a

wall is best.)

select a location that will hold the weight of the unit.

select a location where tubing and drain hose have

 

 

Fig. 1

 

 

 

Tubing length (L)

 

INDOOR

 

 

UNIT

 

 

 

 

 

 

 

 

 

 

 

 

 

Elevation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUTDOOR

 

 

difference (H)

 

 

 

 

 

 

UNIT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fig. 2

CAUTION

Indoor unit

Wall

the shortest run to the outside. (Fig. 1)

allow room for operation and maintenance as well as

unrestricted air flow around the unit. (Fig. 2)

install the unit within the maximum elevation differ-

ence (H) above or below the outdoor unit and within

a total tubing length (L) from the outdoor unit as

For stable operation of the air conditioner, do not install wall-mounted type indoor units less than 1.5 m from floor level.

Minimum height from floor level

1.5 m

Floor level

detailed in Table 1 and Fig. 3.

Install the indoor unit more than 1 meter away from any

antenna or power lines or connecting wires used for

television, radio, telephone, security system, or inter-

com. Electrical noise from any of these sources may

affect operation.

Table 1

Fig. 3

 

Max. Allowable Tubing

Limit of Tubing

Limit of Elevation

Required Amount of

Model

Length at Shipment

Length (L)

Difference (H)

Additional Refrigerant

 

(m)

(m)

(m)

*

 

(g/m)

KRV93 / 123

7.5

15

7

15

 

 

 

 

 

*If total tubing length becomes 7.5 to 15 m (max.), charge additional refrigerant (R410A) by 15 g/m. No additional compressor oil is necessary.