Sanyo SAP-CRV123EH Power Source, Voltage Rating, Performance, Electrical Rating, Features

Models: SAP-CRV93EH SAP-CRV123EH SAP-KRV93EH SAP-KRV123EH

1 77
Download 77 pages 63.4 Kb
Page 6
Image 6
Manual background

Indoor Unit

SAP-KRV123EH

 

 

 

 

 

 

 

Outdoor Unit SAP-CRV123EH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power Source

 

 

 

 

 

220 – 240V Single-phase 50Hz

 

 

 

 

 

 

 

 

 

 

Voltage Rating

 

 

 

 

 

230V

 

 

 

 

 

 

 

 

 

 

 

 

Performance

 

 

 

 

 

Cooling

 

Heating

 

Capacity

 

 

kW

 

3.50 (0.9 – 3.8)

 

4.20 (0.9 – 5.8)

 

 

 

 

 

BTU/h

 

11,900 (3,100 – 13,000)

 

14,300 (3,100 – 19,800)

 

Air circulation (High)

 

 

m3/h

 

500

 

 

530

 

Moisture removal (High)

 

 

Liters/h

 

2.0

 

 

 

 

 

 

 

 

 

 

 

 

Electrical Rating

 

 

 

 

Cooling

 

 

Heating

 

Available voltage range

 

 

V

 

198 – 264

 

Running amperes

 

 

A

 

5.21 (1.19 – 6.21)

 

5.48 (1.18 – 7.09)

 

Power input

 

 

W

 

1,090 (250 – 1,300)

 

1,165 (250 – 1,500)

 

Power factor

 

 

%

 

91

 

 

92

 

C.O.P.

 

 

 

W/W

 

3.21

 

 

3.61

 

Compressor locked rotor amperes

 

A

 

15

 

 

 

 

 

 

 

 

 

 

 

 

Features

 

 

 

 

 

 

 

 

 

 

Controls / Temperature control

 

 

 

Microprocessor / I.C. thermostat

 

Control unit

 

 

 

 

Wireless remote control unit

 

Timer

 

 

 

 

 

ON / OFF 24 hours & Daily program, 1-hour OFF

 

Fan speeds

Indoor / Outdoor

 

 

3 and Auto / 1 (Hi)

 

Airflow direction (Indoor)

Horizontal

 

Manual

 

 

 

 

 

 

Vertical

 

Auto

 

 

Air filter

 

 

 

 

Washable, Anti-Mold

 

Compressor

 

 

 

 

Rotary (DC inverter)

 

Refrigerant / Amount charged at shipment

g

 

R410A / 1,100

 

Refrigerant control

 

 

 

 

Electric expansion valve

 

Operation sound

Indoor: Hi / Me / Lo

dB-A

 

36 / 33 / 29

 

 

34 / 31 / 29

 

 

 

Outdoor: Hi

 

dB-A

 

47

 

 

49

 

Refrigerant tubing connections

 

 

 

Flare type

 

Max allowable tubing length at shipment

m

 

7.5

 

 

Refrigerant

Narrow tube

mm (in.)

 

6.35 (1/4)

 

tube diameter

Wide tube

 

mm (in.)

 

9.52 (3/8)

 

Refrigerant tube kit / Accessories

 

 

 

Optional / Air clean filter

 

 

 

 

 

 

 

 

 

Dimensions & Weight

 

 

 

 

Indoor Unit

 

Outdoor Unit

 

Unit dimensions

Height

 

mm

 

285

 

 

548

 

 

 

Width

 

mm

 

825

 

 

720

 

 

 

Depth

 

mm

 

189

 

 

265

 

Package dimensions

Height

 

mm

 

350

 

 

600

 

 

 

Width

 

mm

 

900

 

 

856

 

 

 

Depth

 

mm

 

255

 

 

362

 

Weight

 

Net

 

kg

 

9.0

 

 

35.0

 

 

 

Shipping

 

kg

 

11.0

 

 

37.0

 

Shipping volume

 

 

m3

 

0.080

 

 

0.186

 

 

 

 

 

 

 

DATA SUBJECT TO CHANGE WITHOUT NOTICE.

Remarks: Rating conditions are:

 

 

 

 

 

 

 

 

 

Cooling: Indoor air temperature

27°C D.B. / 19°C W.B.

 

 

 

Outdoor air temperature

35°C D.B. / 24°C W.B.

 

 

Heating: Indoor air temperature

20°C D.B.

 

 

 

 

 

 

Outdoor air temperature

7°C D.B. / 6°C W.B.

 

 

 

 

6

Page 6
Image 6
Sanyo SAP-CRV123EH Power Source, Voltage Rating, Performance, Electrical Rating, Features, Dimensions & Weight