Sanyo SAP-KRV93EH Outdoor Unit, Control PCB A / Control PCB B, Compressor, Fan & Fan Motor

Models: SAP-CRV93EH SAP-CRV123EH SAP-KRV93EH SAP-KRV123EH

1 77
Download 77 pages 63.4 Kb
Page 9
Image 9
2-2-2. Outdoor Unit

2-2-2. Outdoor Unit

Outdoor Unit SAP– CRV93EH

Control PCB (A) / Control PCB (B)

 

 

 

Part No.

 

CB-CRV93EH (POW-CRV93GJH)

 

Controls

 

Microprocessor

 

Control circuit fuse

 

250V, 20A

 

 

 

 

 

 

Compressor

 

 

 

Type

 

DC Rotary (Hermetic)

 

Compressor model / Nominal output

 

G4C090LU1ER / 600W

 

Compressor oil … Amount

cc

FV50S … 320

 

Coil resistance (Ambient temp. 20°C)

Ω

U – V: 0.81

 

 

 

 

 

V – W: 0.81

 

 

 

 

 

W – U: 0.81

 

Safety devices

 

 

 

 

CT (Peak current cut-off control)

 

YES

 

 

Compressor discharge temp. control

 

YES

 

 

Operation cut-off control in abnormal ambient temp.

 

Run capacitor

µF

 

 

 

 

VAC

 

Crankcase heater

 

 

 

 

 

Fan & Fan Motor

 

 

 

Type … Fan / Fan motor

 

Propeller / AC motor

 

Q’ty … Dia.

mm

1 … 370

 

Fan motor model … Q’ty

 

IB-976-501 … 1

 

No. of poles … Rough measure rpm (Cool / Heat)

6 … 700 / 700

 

Nominal output

W

20

 

Coil resistance (Ambient temp. 20°C)

Ω

WHT – BRN: 213

 

 

 

 

 

RED (PNK) – WHT: 168

 

 

 

 

 

— :

 

Safety devices Type

 

Thermal fuse

 

 

 

Operating temp. Open

°C

150

 

 

 

Close

°C

 

Run capacitor on control PCB (A)

µF

2.0

 

 

 

 

VAC

440

 

 

 

 

Heat Exchanger Coil

 

 

 

Coil

 

Aluminum plate fin / Copper tube

 

Rows

 

2

 

Fin pitch

mm

1.4

 

Face area

m2

0.288

 

 

 

External Finish

 

Acrylic baked-on enamel finish

 

 

 

 

 

 

DATA SUBJECT TO CHANGE WITHOUT NOTICE.

9