(4)Indoor unit does not run.

4. Service procedures

(4)Indoor unit does not run.

(Indoor fan and louver motor do not run.

P.C.B. Ass’y is defective.

0630_X_S

(5)Some part does not operate.

(1)Indoor fan does not run.

• Check fan rotation.

Rotate the fan gently once or twice by hand.

Check resistance of fan motor winding.

OK

Check fan motor capacitor.

OK

Fan cannot be rotated.

Check fan casing

 

 

 

 

 

Remove foreign

for foreign matter

 

 

 

on the inside.

 

 

matter or repair.

 

 

 

 

 

 

 

 

Fan motor burnout

 

 

 

 

 

Repair or replace.

or foreign matter

 

 

 

in bearing.

 

 

 

 

 

 

 

 

 

 

Relay RY1 or RY2 on the

P.C.B. Ass’y is defective.

0631_X_S

(2) Louver motor does not run.

Check resistance of louver motor winding.

OK

P.C.B. Ass’y or remote control unit is defective.

0632_X_S