1. Specifications
1
(B) Outdoor Unit
| MODEL No. |
|
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
| |||
| Source |
|
|
|
|
| 380 - 400 - 415 V / 3 phase / 50 Hz |
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
| |||
| Compressor |
|
|
| Rotary (Hermetic) |
|
|
| Scroll (Hermetic) | ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
| Model...Code No. |
|
|
|
| C - R243H8T |
|
|
| ZR61KC - TFD - 522 | |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| Nominal output |
| W |
|
|
| 2,400 |
|
|
| 3,750 | ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| Compressor oil |
| cc |
|
|
| 1,350 |
|
|
| 2,130 | ||||
|
|
|
|
|
|
|
|
|
|
|
|
| |||
| Coil resistance |
| Ω | T – R | : | 5.54 , R – S : | 5.54 |
| T1 – T2 : 2.72 , T2 – T3 : 2.72 | ||||||
| (Ambient temperature 25°C ) |
|
| S – T | : | 5.54 |
|
|
| T3 – T1 : 2.72 |
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
| Refrigerant amount at shipment |
| kg |
|
| R 22 - 4.0 |
|
|
| R 22 - 4.3 | |||||
|
|
|
|
|
|
|
|
|
|
|
| ||||
| Safety devices |
|
| Internal type |
| External type |
| Internal type |
| External type | |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
| Overload relay models |
|
| — |
|
| FMSA |
|
| — |
| FMSA | ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
| Operating temperature | Open | °C | 120 ± | 5 |
| — |
|
|
| 130 |
| — | |
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
| Close °C | 98 ± 11 |
| — |
|
|
| 61 |
| — | |||
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
| Operating ampere (at 25°C) |
| A | — |
|
| 6A, 110 % |
|
| — |
| 10A, 110% | ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Run capacitor |
| V, μF |
|
|
|
|
| — |
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| High pressure switch |
|
|
|
|
|
|
| ACB - 1TB07 |
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| Set pressure | OFF | kg/cm2 |
|
|
|
|
| 30 +0.5+2.0 |
|
|
| |||
|
|
| ON | kg/cm2 |
|
|
|
|
| 24 ± 2.0 |
|
|
| ||
| Fan (Number...diameter) |
| mm |
|
|
|
| Propeller (2...ø460) |
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Fan motor |
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
| |||
| Model...Nominal output |
| W |
|
|
|
| KFC6S - 91C5PX2...100WX2 |
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| No. of pole...rpm (230 V, High) |
| rpm |
|
|
|
|
| 6...871 |
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Coil resistance |
| Ω |
|
|
|
| BRN | – WHT | : | 61.0 |
|
| ||
| (Ambient temperature 20°C) |
|
|
|
|
|
| WHT – YEL | : | 64.3 |
|
| |||
|
|
|
|
|
|
|
|
| YEL | – PNK | : | 17.7 |
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Safety device |
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Operating temperature | Open | °C |
|
|
|
|
| 130 ± | 8 |
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
| Close | °C |
|
|
|
|
| 79 ± 15 |
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
| |||
| Run capacitor | VAC, μF |
|
|
|
| 440V, 5 μF / 440 V, 5 μF |
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Heat exchanger |
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
| |||
| Coil |
|
|
|
|
|
| Aluminum plate fin / Copper tube |
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| Rows...fin pitch |
| mm2 |
|
|
|
|
| 2...2.0 |
|
|
| |||
| Face area |
| m2 |
|
|
|
|
| 1.08 |
|
|
|
SM830043