![1. Specifications](/images/new-backgrounds/34193/3419315x1.webp)
1. Specifications
1
1-1 Unit Specifications
| MODEL No. |
|
| Indoor Unit |
|
|
| |||||||||
|
|
|
|
| Outdoor Unit |
|
|
| ||||||||
| POWER SOURCE |
|
|
|
|
|
|
|
|
|
| 220 - 230 - 240 V / 1 Phase / 50 Hz | ||||
|
|
|
|
|
|
|
|
|
|
| ||||||
| PERFORMANCE |
|
|
|
|
|
|
|
|
|
| Cooling |
| |||
| Capacity |
|
|
| kW |
|
|
|
|
| 7.3 |
| ||||
|
|
|
|
|
|
|
|
| ||||||||
|
|
|
|
|
|
| BTU / h |
|
|
|
|
| 25,000 |
| ||
| Air circulation (Hi/Me/Lo) |
|
|
| m3 / h |
|
|
| 1,140/1,020/840 |
| ||||||
| Moisture removal(High) |
|
|
| Liters/h |
|
|
|
|
| 3.4 |
| ||||
| ELECTRICAL RATINGS |
|
|
|
|
|
|
|
|
|
|
| ||||
| Voltage rating |
|
|
|
| V |
|
| 220 |
| 230 | 240 | ||||
| Available voltage range |
|
|
|
| V |
|
|
|
|
| 198 - 264 |
| |||
| Running amperes* |
|
|
|
| A |
|
| 14.5 |
| 14.6 | 15 | ||||
| Max. running amperes** |
|
|
|
| A |
|
| 20.1 |
| 19 | 19.2 | ||||
| Power input |
|
|
| kW |
|
| 2.97 |
| 3.02 | 3.11 | |||||
| Power factor |
|
|
| % |
|
| 93.1 |
| 89.9 | 86.4 | |||||
| C.O.P |
|
|
| W / W |
|
| 2.46 |
| 2.42 | 2.35 | |||||
| Max. starting amperes |
|
|
|
| A |
|
| 69 |
| 72 | 75 | ||||
| FEATURES |
|
|
|
|
|
|
|
|
|
|
|
|
| ||
| Controls |
|
|
|
|
|
|
|
|
| Microprocessor |
| ||||
| Timer |
|
|
|
|
|
|
| ON / OFF |
| ON/OFF | |||||
| Fan speed (Indoor) |
|
|
|
|
|
|
|
| 3 and Automatic control | ||||||
| Airflow direction (Indoor) |
|
|
|
|
|
| Automatic (Remote control) | ||||||||
| Air filter |
|
|
|
|
|
|
|
| Washable, easy access | ||||||
| Remote controller (Accessory) |
|
|
|
|
|
| |||||||||
| Refrigerant control |
|
|
|
|
|
|
|
|
| Capillary tube |
| ||||
| Drain pump (drain connection) |
|
|
|
|
|
|
| No (20A, OD26mm) |
| ||||||
| Compressor |
|
|
|
|
|
|
|
|
|
| Rotary |
| |||
| Operation sound |
| Indoor - Hi/Me/Lo | dB - A |
|
|
|
|
| 45 / 41 / 37 |
| |||||
|
|
|
| Outdoor - Hi |
| dB - A |
|
|
|
|
| 53 |
| |||
| REFRIGERANT TUBING |
|
|
|
|
|
|
|
|
|
|
| ||||
| Limit of tubing length |
|
|
| m (ft.) |
|
|
|
|
| 40 (131) |
| ||||
| Limit of tubing length at shipment |
| m (ft.) |
|
|
|
|
| 15 (49) |
| ||||||
| Limit of elevation difference |
| m (ft.) |
|
| Outdoor unit is higher than indoor unit: 40 (131) | ||||||||||
| between the two units |
|
|
|
|
|
|
| Outdoor unit is lower than indoor unit: 25 (82) | |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
| Refrigerant tube |
|
| Narrow tube |
| mm (in) |
|
|
|
|
| 6.35 (1 / 4) |
| |||
| outer diameter |
|
| Wide tube |
| mm (in) |
|
|
| 15.88 (5 / 8) |
| |||||
| Refrigerant amount at shipment |
|
| kg |
|
|
|
|
| R22 - 2.4 |
| |||||
| DIMENSIONS & WEIGHT |
|
|
|
|
|
| Indoor unit |
| Outdoor unit | ||||||
| Unit dimensions |
|
| Height |
| mm (in) |
|
| 185 |
|
| 735 | ||||
|
|
|
|
| Width |
| mm (in) |
|
| 1,270 | (50) |
|
| 940 | (37) | |
|
|
|
|
| Depth |
| mm (in) |
|
| 670 |
| 340 | ||||
| Package dimensions |
|
| Height |
| mm (in) |
|
| 271 |
| 826 | |||||
|
|
|
|
| Width |
| mm (in) |
|
| 1,370 |
| 1,016 | (40) | |||
|
|
|
|
| Depth |
| mm (in) |
|
| 782 |
| 416 | ||||
| Net weight |
|
|
| kg (lb) |
|
| 28 | (62) |
|
| 68 | (150) | |||
| Shipping weight |
|
|
| kg (lb) |
|
| 36 | (79) |
|
| 74 | (163) | |||
| Shipping volume |
|
| m3 (Cu. ft.) |
|
| 0.29 | (10.2) |
|
| 0.349 | (12.3) |
DATA SUBJECT TO CHANGE WITHOUT NOTICE
Cooling :
Rating conditions(*) : Indoor air temperature 27 °C DB / 19 °C WB, Outdoor air temperature 35 °C DB Full load conditions(**) Indoor air temperature 35 °C DB / 25 °C WB, Outdoor air temperature 50 °C DB
SM830043
– 8 –