2
Operation Controller with Receiver (Separated from Indoor Unit) for K and U Types
A: Operation controller
B: Remote control receiver
C: ON/OFF operation button
D: SWEEP button
E: SERVICING switches
F: Switch
G: ADDRESS switch
H: OPERATION lamp
I: TIMER lamp
J: STANDBY lamp
K: FILTER lamp
A: Operation controller | You can operate this air conditioner using the |
(separated from indoor unit) | operation controller without the wireless remote controller. |
B:Remote control receiver This section picks up infrared signals from the wireless remote controller (transmitter).
C:ON/OFF operation button This button is for turning the air conditioner on and off (automatically setting cooling or heating operation).
D: SWEEP button | Use this button to make the airflow direction sweep up and down | ||
|
|
| automatically. |
|
|
|
|
E: SERVICING switches | These switches are used only when servicing the air conditioner. | ||
|
|
| Do not use these SERVICING switches for normal operation. |
|
|
| |
|
|
| |
|
|
|
|
F: Switch | Usually set this switch in to the NORMAL position. | ||
|
|
|
|
G: ADDRESS switch | When operating the air conditioner by using the wireless remote controller, be | ||
|
|
| sure to match the number on this switch with the number set on the wireless |
|
|
| remote controller. Otherwise, the remote control will not work. |
|
|
|
|
H: OPERATION lamp | This lamp lights when the appliance is turned on. | ||
|
|
|
|
I: TIMER lamp | This lamp lights when the system is being controlled by the timer. | ||
|
|
|
|
J: STANDBY lamp | When the unit is in the heating standby condition, the STANDBY lamp lights. | ||
|
|
|
|
K: FILTER lamp | This lamp lights when the filter needs cleaning. | ||
|
|
|
|
|
|
| Turning off the ON/OFF operation button does not |
|
|
| disconnect the power. Use the main power switch to turn off |
|
|
| the power completely. |
2 - 6 |