Sanyo TM-SH80UG, SHA-KC64UG, RCS-SH80UG, RCS-SH80UA When setting the program operation erroneously

Models: RCS-SH80UA RCS-SH80UG SHA-KC64UG TM-SH80UG

1 64
Download 64 pages 22.45 Kb
Page 48
Image 48
6.When setting the program operation erroneously

6.When setting the program operation erroneously

If the ERROR indicator Programming shown below will cause ERROR setting. blinks while you are setting program operation, take the following steps to correct times you set.

1While the Manual background blinks, the ON-time of the program operation that is incorrectly set also blinks.

2 Press the SET button to make the time to be corrected blink.

3 Correct the time using the HH or/and MM button.

4 Press the SET button. If the corrected time is acceptable, the Manual background turns off. 5 Press the PROGRAM button to complete the correction.

NOTE

Programming shown below will cause ERROR setting.

(1)Programmed operation periods overlap between programs. Example: ON-time OFF-time

(2)The OFF-time is earlier than the ON-time. Example: ON-time OFF-time

(3)The OFF-time and ON-time is the same. Example: ON-time OFF-time

0:00 Manual background 23:59

ON

OFF

ONOFF

0:00 Manual background 23:59

OFFON

0:00 Manual background 23:59

ON/OFF

3

(4)

Only the ON-time or OFF-time is programmed.

 

 

 

 

 

 

 

 

Example: ON-time OFF-time

0:00

 

 

 

 

 

23:59

 

 

 

 

 

 

 

(not programmed)

 

ON

 

 

 

 

 

 

 

 

 

 

The following examples will not cause ERROR setting.

 

 

 

 

 

 

 

(1)

The OFF-time is the same with the ON-time of the subsequent operation period.

 

 

 

 

Example: ON-time OFF-time

0:00

 

 

 

 

 

23:59

 

ON

 

 

OFF

 

 

 

 

 

 

 

 

 

 

 

ON

OFF

 

 

 

 

 

 

 

 

 

 

 

 

(2)The programmed period is earlier than the preceding period. Example: ON-time OFF-time

By pressing the PROGRAM button, programs are arranged in order of time.

 

 

 

 

Example: ON-time OFF-time

0:00

 

 

 

 

 

23:59

 

 

 

ON

 

 

 

 

 

 

OFF

 

 

ON

 

OFF

 

 

 

 

 

 

 

 

 

(3)Both the ON-time and OFF-time are 0:00. Example: ON-time OFF-time

*This program is for 24-hour continuous operation.

3 - 10

OI-432-03 - 10EG

Page 48
Image 48
Sanyo TM-SH80UG When setting the program operation erroneously, Programming shown below will cause ERROR setting