3. BLC

3-1. Setting the light measuring area characteristics (size, position and distribution) for the MANUAL 1 setting

1Set the BLC switch (9) to ON. The on-screen setting for BLC will automatically switch to ON. Press the CURSOR (j or l) button to select the on-screen ON setting (get it flashing), then press the SET button. The adjustment sub-menuADJUSTMENT FOR BLC

will be displayed.

ON

CURSOR

MENU FOR ADJUSTMENT

SET

 

 

 

SYNC

INT

OFF

 

IRIS

AI

 

BLC

ON

 

 

2Press the CURSOR (d or c) button until MANUAL 1 is selected, then press the SET button. The adjustment sub-menuSIZE” will be displayed.

ADJUSTMENT FOR BLC

BLC MODE

MANUAL1

PRESET1_PRESET2_MANUAL1_MANUAL2

3Press the CURSOR buttons to set the size of the area, then

press the SET button. The adjustment sub-menuPOSITION” will be displayed.

CURSOR

CURSOR

 

 

ADJUSTMENT FOR BLC

 

ADJUSTMENT FOR BLC

 

(SIZE)(p)

 

(SIZE)

SET

 

 

 

CURSOR

CURSOR

(l)

 

(o)

 

(j)

 

 

 

 

4Press the CURSOR buttons to move (up, down, right, left) the area to the desired position, then press the SET button. The adjustment sub-menuWINDOW WEIGHTING” will be displayed.

ADJUSTMENT FOR BLC

(POSITION)

Note:

The WINDOW WEIGHTING default values are W0 : 1, W1 : 1, W2

:3, W3 : 3, W4 : 15 (the value for W4 is fixed to 15 and cannot be modified).

ADJUSTMENT FOR BLC

BLC MODE

PRESET 1

ADJUSTMENT FOR BLC

(SIZE)

ADJUSTMENT FOR BLC

(POSITION)

WINDOW WEIGHTING

W0

1

W1

1

W2

3

W3

3

W4(FIX)

15

PRESET

OFF

END