PARTS NAMES

1

2 ADJ.

1 LOCK

3

Flange-back adjustment

If the pick-up surface is not correctly positioned with relation to the lens focal point, the picture will be out of focus (in particular when using auto-iris power zoom lenses, sold separately). If that is the case, adjust the flange-back position as described below.

1Using a + screwdriver, loosen the FLANGE BACK LOCK screw (M2:+).

Set the zoom lens to the maximum telephoto position, set the focus using the focus ring on the lens.

2Set the zoom lens to the maximum wide angle position, set the focus using the FLANGE BACK ADJ. screw.

3Repeat steps 2 and 3, until the image stays in focus when changing from a telephoto shot to a wide angle shot. When the setting is complete, tighten the FLANGE BACK LOCK screw.

MOUNTING THE LENS

Check the lens mount

Do not use a lens if the length “L” is more than 5 mm. That may damage the camera and prevent proper installation.

L

Installation of a DC type auto-iris lens (sold separately)

A 1/3 inch CS mount type lens without EE amplifier circuit that only uses a DC power source. This camera can receive (the A.I. LENS switch to the DC type) a CS mount type lens without the need of an adaptor.

If the lens plug shape or wiring does not correspond, please install the supplied plug as indicated in the pin layout table.

English 7