Alarm Setting

ID3

4 Click the [FRAME RATE] drop-down list box and select the playback speed.

Note: The alarm data can be saved as still images on a computer. Right-click on an image that is being played back to display a pop-up menu. Refer to “Saving Images into a Computer” (p. 31) for details on the method of saving images.

5 Click the [LIVE VIEW] button in the main menu.

The display will return to the live image screen.

BUFFER DATA VIEW screen

1 2 3 6

4 5 7

1[TOP] button

This is used to return to the start of the alarm data.

2[PLAY] button

This is used to start playback.

3[STOP] button

This is used to stop playback.

4[PRE/POST] display

PRE” (playback of pre-recording images) and

POST” (playback of post-recording images) are automatically displayed during playback, and then after playback finishes, “END” is displayed. If there are no pre-recording images, playback starts from the post-recording images.

5[LIST] button

This is used to return to the ALARM DATA LIST screen.

6[FRAME RATE] display

The playback speed is selected from a drop-down list box. Playback starts automatically from the start of recording at the speed selected, and continues until playback is finished.

Available settings:

SLOW: Slow playback speed

NORMAL: Normal playback speed

FAST: Fast playback speed

Note: The actual playback speed will vary depending on the alarm data volume and the network status.

7Playback screen