System Setup (Setup) (Continued)

1Language (Select Language):

Each number corresponds to the number by each language displayed in the LANGUAGE screen under

System Setup ( ).

Check the display language and select the proper number.

2Communications (Communication Setup):

bWhen controlling a camera connected to our video equipment (Video)

Upon purchasing, the communication settings are set for connecting to our video equipment (DVR/ MUX), and the settings do not need to be changed.

For communication setup for competitor video equipment, see the “Communications Chart”. (P86)

Type:

This displays the equipment (DVR/MUX) connected to the video communication terminal. Changing the type will require changing the Protocol and Baudrate as well.

bCommunication setup when using competitor cameras (Telemetry B)

Connector: Telemetry

Operating a camera by connecting this unit to camera using modular cable.

Protocol:

This is the communication protocol used on this unit.

Every time the communication protocol is changed, “Baudrate” is restored to the default value.

Baudrate:

Select the data transmissions speed for the camera connected to camera communication terminal B.

3Buzzer/Display

(Buzzer and Menu Display Setup):

Select and check the setup for each item.

Key pressed: Button operation

This setting sounds a buzzer when a button on the screen is pressed.

Selections: Min (soft), Max (loud)

• Protocol:

• Joystick: Joystick Operation

English

This shows the communication protocol (SANYO DVR/MU) used on this unit.

BaudRate:

Select the data transmissions speed (19200) for the connected video equipment.

Address:

This is the unit address.

bCommunication setup when using our video equipment and cameras (Telemetry A)

Upon purchasing, the communication settings are set to connect our video equipment to cameras using coaxial cables.

Communication uses the video communication terminal (VIDEO).

Connector:

Video: Connecting cameras via video equipment.

Telemetry: Operating a camera by connecting this unit to camera using modular cable.

Protocol:

The communication protocol used on this unit is SANYO SSP. Every time the communication protocol is changed, “Baudrate” is restored to the default value.

Baudrate:

Select the data transmissions speed for the camera connected to camera communication terminal A.

Note: When “Video” is selected for “Connector”, the Video data transmission speed is fixed, and “Baudrate” cannot be set.

This setting sounds a buzzer when the joystick is moved.

Selections: No, Yes

Serial error: Serial error detection

This setting sounds a buzzer upon a serial communication error.

Selections: No, Yes

Matrix Alarm:

Selections: No, Yes

Power Saving:

Selections: No, Yes

4Password (Password Setup):

Enter when setting a password for the following items.

Turn on: Upon power ON

Reset Alarms: Upon alarm reset

Change parameters: Upon accessing setup menu

Level 1: Upon calling up “Level 1” functions

Level 2: Upon calling up “Level 2” functions

Level 3: Upon calling up “Level 3” functions

For level settings, see the “Jump page” on P75.

63Software