Stop Bit Selection (DSW1-4). Selects the number of stop bits to end each byte
transmission.
Baud Rate Selection (DSW1-5, DSW1-6). Selects the data rate (bps) for the
RS232 port.
Protocol Selection (DSW1-7, DSW1-8). Selects the flow control and status
reporting protocols. See Section 6: Interface Specifications for more information.
(* Will select protocol for M-8400 if DSW2-8 is ON)
Printer Set Up
Print Mode Selection (DSW2-1). Selects between direct thermal printing on
thermally sensitive paper and thermal transfer printing using a ribbon.
Sensor Type Selection (DSW2-2). Selects between the use of a label gap or a
reflective Eye-Mark detector.
Page 3-2 PN9001074 Rev. B SATO CL Series ā€œeā€ Printers
Section 3. Configuration
DSW1-5 DSW1-6 SETTING
Off Off 9600
Off On 19200
On Off 38400
On On 57600 12345678
ON
OFF
DSW1
DSW1-7 DSW1-8 SETTING
Off Off Rdy/Bsy
Off On Xon/Xoff
On Off Bi-Com 3
On On Bi-Com4* 12345678
ON
OFF
DSW1
DSW2-1 SETTING
Off Therm Xfr
On Direct Therm
12345678
ON
OFF
DSW2
DSW2-2 SETTING
Off Gap
On Eye-Mark
12345678
ON
OFF
DSW2
DSW1-4 SETTING
Off 1 Stop Bit
On 2 Stop Bits
12345678
ON
OFF
DSW1