ZL0093-0A 11/2011

EM3555

Specifications

Type

 

Description

 

 

 

Environmental Conditions

 

Operating Temperature

 

-30° to 70°C (-22° to 158°F)

 

 

 

Storage Temperature

 

-40° to 85°C (-40° to 185°F)

 

 

 

Humidity Range

 

<95% RH (non-condensing)

 

 

 

Altitude of Operation

 

3 km max.

 

 

 

Metering Category

 

US and Canada

 

CAT III; for distribution systems up to 347 V L-N /600 VAC L-L

 

 

 

CE

 

CAT III; for distribution systems up to 300 V L-N /480 VAC L-L

Dielectric Withstand

 

Per UL 508, EN61010

 

 

 

Conducted and Radiated

 

FCC part 15 Class B, EN55011/EN61000 Class B;

Emissions

 

(residential and light industrial)

Conducted and Radiated

 

EN61000 Class A (heavy industrial)

Immunity

 

 

 

 

 

Safety

 

US and Canada (cULus)

 

UL508 (open type device)/CSA 22.2 No. 14-05

 

 

 

Europe (CE)

 

EN61010-1:2001

 

 

 

* External DC current limiting is required, see fuse recommendations.

For use in a Pollution Degree 2 or better environment only. A Pollution Degree 2 environment must control conductive pollution and the possibility of condensation or high humidity. Consideration must be given to the enclosure, the correct use of ventilation, thermal properties of the equipment and the relationship with the environment.

Always use this product in the manner specified or the protection provided by the product may be impaired.

Provide a disconnect device to disconnect the meter from the supply source. Place this device in close proximity to the equipment and within easy reach of the operator, and mark it as the disconnecting device. The disconnecting device shall meet the relevant requirements of IEC 60947-1 and IEC 60947-3 and shall be suitable for the application. In the US and Canada, disconnecting fuse holders can be used. Provide overcurrent protection and disconecting device for supply conductors with approved current limiting devices suitable for protecting the wiring. If the equipment is used in a manner not specified by the manufacturer, the protection provided by the device may be impaired.

FCC PART 15 INFORMATION

NOTE: This equipment has been tested by the manufacturer and found to comply with the limits for a class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a residential environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area may cause harmful interference in which case the user will be required to correct the interference at his own expense. Modifications to this product without the express authorization of the manufacturer nullify this statement.

N998

© 2011 Schneider Electric All Rights Reserved.