16.TROUBLESHOOTING
PROBLEM | POSSIBLE CAUSE | REASON/SOLUTION |
No reading on the | Charger is not plugged in. | Plug the charger into an AC |
ammeter. |
| outlet. |
| No power at the receptacle. | Check for open fuse or circuit |
|
| breaker supplying AC outlet. |
| Clips are not making a good | Check for poor connection to |
| connection to the battery. | battery and frame. Make sure |
|
| connection points are clean. |
|
| Rock clips back and forth for a |
|
| better connection. |
| Connections are reversed. | Unplug the charger and reverse |
|
| the clips. |
| Battery is defective (will not | Have battery checked. |
| accept a charge). |
|
| 1.5, 2, 4 or 5 amp charge rate is | Ammeter may show no activity at |
| being used. | the 1.5A, 2A, 4A or 5A charge rate. |
Ammeter reading stays high. | Battery is severely discharged. | Continue charging battery for two |
|
| more hours. If problem continues, |
|
| have the battery checked. |
| Wrong battery voltage. | Verify the voltage settings on the |
|
| charger are correct. |
Ammeter reads less than | Extension cord is too long or wire | Use a shorter or heavier gauge |
selected charge rate when | gauge is too small. | extension cord. |
charging a discharged | Weak cell or sulfated plate in | A sulfated battery will eventually |
battery. | ||
| battery. | take a normal charge if left |
|
| connected. If the battery will not |
|
| take a charge, have it checked. |
| Battery is only partially discharged. | Continue to charge the battery. |
|
|
|
The charger is making an | Circuit breaker is cycling. | The settings may be wrong. |
audible clicking sound. |
| Check the charger settings. |
| Battery is defective. | Have the battery checked. |
| Shorted battery cables or clips. | Circuit breaker cycles when |
|
| current draw is too high. Check for |
|
| shorted cables or clips and replace |
|
| if necessary. |
| Severely discharged battery, but | The battery may not want to |
| otherwise it is a good battery. | accept a charge due to a run- |
|
| down state. Allow charging to |
|
| continue until battery has a |
|
| chance to recover sufficiently to |
|
| take a charge. If more than 20 |
|
| minutes, stop charging and have |
|
| the battery checked. |
| Reverse connections at battery. | Shut the charger off and correct |
|
| the lead connections. |
• 13 •