Seagate FR-A7AY instruction manual Extension Analog Output, Wiring Example

Models: FR-A7AY

1 31
Download 31 pages 43.88 Kb
Page 16
Image 16

4EXTENSION ANALOG OUTPUT

4.1 Wiring Example

By setting the Pr. 306 to Pr. 312 values, analog signals such as the output frequency and output current can be output from the voltage output terminal (AM0) and current output terminal (AM1).

Connect the voltmeter or ammeter as shown below:

MCCB

Inverter

 

Power

 

 

supply

 

 

(Voltmeter)

0 to 10VDC

 

+

 

 

 

FR-A7AY

-

 

AM0

 

 

 

 

AM1

(Ammeter)

 

AMC

+

 

 

0 to 20 mADC

 

-

 

 

Motor

IM

CAUTION

The wiring length between the FR-A7AY and the voltmeter/ammeter should be 10m maximum.

4