EXTENSION ANALOG OUTPUT

4.5.4Analog signal adjustment [Pr. 307, Pr. 308, Pr. 311, Pr. 312]

Use Pr. 307 or Pr. 311 to set for zero analog output (meter points 0).

In addition, use Pr. 308 or Pr. 312 to set for maximum analog output (full-scale).

Use Pr. 307 to set the value for zero analog output and Pr. 308 for maximum analog output when outputting the same signal from terminals AM0 and AM1.

Use Pr. 307(AM1) and Pr. 311(AM0) to set the value for zero analog output and Pr. 308(AM1) and Pr. 312(AM0) for maximum analog output when outputting different signals from terminals AM0 and AM1. (Refer to page 15.)

 

When Pr. 309 = 0, 1

 

When Pr. 309 = 10, 11

Analog output

Output signal value (Pr. 308 or

Analog output

Analog output

Current Voltage

 

Current Voltage

value (Pr. 308 or

Pr. 312) for maximum analog output

(AM1) (AM0)

(AM1) (AM0)

Pr. 312) for

 

 

 

20mA 10V

 

20mA 10V

maximum

 

 

 

output signal

0

Output signal

0

Output signal

value

value

 

Output signal value (Pr. 307 or

 

Output signal value (Pr. 307 or

 

Pr. 311) for zero analog output

 

Pr. 311) for zero output signal

 

 

 

 

REMARKS

 

REMARKS

= Pr. 308, Pr. 311 = Pr. 312, the output

 

When Pr. 307

Pr. 308, Pr. 311 Pr. 312, the output

When Pr. 307

 

values at terminals AM0 and AM1 are always zero.

values at terminals AM0 and AM1 are values set in

 

 

 

parameters always.