EXTENSION ANALOG OUTPUT
4.4 Extension Analog Output Function Parameter List
Parameter | Name | Setting Range | Minimum | Initial | |
Number | Increments | Value | |||
|
| 1 to 3, 5, 6, 8, |
|
| |
306 | Analog output signal selection | (9), 10 to 14, 17, | 1 | 2 | |
|
| 21, 24, 50, 52, 53 |
|
| |
307 | Setting for zero analog output | 0 to 100% | 0.1 | 0% | |
308 | Setting for maximum analog output | 0 to 100% | 0.1 | 100% | |
309 | Analog output signal voltage/current | 0, 1, 10, 11 | 1 | 0 | |
switchover | |||||
|
|
|
| ||
|
| 1 to 3 , 5, 6, 8, |
|
| |
310 | Analog meter voltage output | (9), 10 to 14, 17, | 1 | 2 | |
|
| 21, 24, 50, 52, 53 |
|
| |
311 | Setting for zero analog meter | 0 to 100% | 0.1 | 0% | |
voltage output | |||||
|
|
|
| ||
312 | Setting for maximum analog meter | 0 to 100% | 0.1 | 100% | |
voltage output | |||||
|
|
|
| ||
323 | AM0 0V adjustment | 900 to 1100% | 1 | 1000% | |
324 | AM1 0mA adjustment | 900 to 1100% | 1 | 1000% | |
C0(900) | FM terminal calibration | | | | |
C1(901) | AM terminal calibration | | | |
REMARKS
For Pr. 306 and Pr. 310, write is enabled even when "0" is set in Pr. 77.