DIGITAL OUTPUT

5.2 Terminals

By setting the Pr. 313 to Pr. 319 values, output signals available with an inverter as standard can be output from the open collector terminals.

(1)Open collector output specifications: Permissible load 24V, 0.1ADC

(2)The circuit logic is the same as that of the inverter.

For details of changing the control logic, refer to the inverter manual (basic).

AMC

NC

SE

Y3

Y4

Y5

Y6

AM0

AM1

NC

SE

Y0

Y1

Y2

Terminal Symbol

Terminal Name

Description

Y0

 

Use Pr. 313 to assign functions.

Y1

 

Use Pr. 314 to assign functions.

Y2

Digital output

Use Pr. 315 to assign functions.

Y3

Use Pr. 316 to assign functions.

terminals

Y4

Use Pr. 317 to assign functions.

 

Y5

 

Use Pr. 318 to assign functions.

Y6

 

Use Pr. 319 to assign functions.

SE

Common

This is a common terminal (for sink and

terminal

source).

 

AM0

 

 

AM1

Used for analog output function. (Refer to page 11)

AMC

 

 

NC (empty)

Do not use.

 

22

Page 27
Image 27
Seagate FR-A7AY instruction manual Digital Output