Table 3:

ST3750630SS DC power requirements

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ST3750630SS

 

 

 

 

 

 

 

 

3 Gbit mode

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Notes

(Amps)

 

(Amps)

 

 

 

 

 

 

 

 

 

 

 

 

 

Voltage

 

 

 

 

 

 

 

+5V

 

+12V [2]

 

 

 

 

 

 

 

 

 

 

 

 

 

Regulation

 

 

 

 

 

 

[5]

±5%

 

 

±5% [2]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

[1] [6]

0.60

 

 

0.50

 

Avg idle current DCX

 

 

 

 

 

Maximum starting current

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(peak DC) DC

[3]

0.90

 

 

2.00

 

(peak AC) AC

[3]

1.10

 

 

3.50

 

 

 

 

 

 

 

 

Delayed motor start (max) DC

[1] [4]

0.60

 

 

0.17

 

Peak operating current:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

[1]

0.62

 

 

0.78

 

Typical DCX

 

 

 

 

 

Maximum DC

[1]

0.74

 

 

0.82

 

Maximum (peak) DC

 

1.15

 

 

1.75

 

 

 

 

 

 

 

 

 

Table 4:

ST3500620SS DC power requirements

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3 Gbit mode

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Notes

(Amps)

 

 

(Amps)

 

 

 

 

 

 

 

 

 

 

 

 

Voltage

 

 

 

 

 

 

 

+5V

 

 

+12V [2]

 

 

 

 

 

 

 

 

 

 

 

 

 

Regulation

 

 

 

 

 

 

[5]

±5%

 

 

±5% [2]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

[1] [6]

0.60

 

 

0.50

 

Avg idle current DCX

 

 

 

 

 

Maximum starting current

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(peak DC) DC

[3]

0.90

 

 

2.00

 

(peak AC) AC

[3]

1.10

 

 

3.50

 

 

 

 

 

 

 

 

Delayed motor start (max) DC

[1] [4]

0.60

 

 

0.17

 

Peak operating current:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

[1]

0.62

 

 

0.78

 

Typical DCX

 

 

 

 

 

Maximum DC

[1]

0.74

 

 

0.82

 

Maximum (peak) DC

 

1.15

 

 

1.75

 

 

 

 

 

 

 

 

 

 

 

 

 

 

[1]Measured with average reading DC ammeter or equivalent sampling scope. Instantaneous +12V current peaks will exceed these values. Power supply at nominal voltage. N (number of drives tested) = 6, 35 Degrees C ambient.

[2]For +12 V, a –10% tolerance is allowed during initial spindle start but must return to ±5% before reaching 7,200 RPM. The ±5% must be maintained after the drive signifies that its power-up sequence has been completed and that the drive is able to accept selection by the host initiator.

[3]See +12V current profile in Figure 2.

24

Barracuda ES.2 SAS Product Manual, Rev. G

Page 30
Image 30
Seagate ST31000640SSIM manual ST3750630SS DC power requirements, ST3500620SS DC power requirements