Table 3: | ST3750630SS DC power requirements |
|
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
| ST3750630SS | ||||
|
|
|
|
|
|
|
| 3 Gbit mode |
|
| ||
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
| Notes | (Amps) |
| (Amps) | ||
|
|
|
|
|
|
|
|
|
|
|
|
|
Voltage |
|
|
|
|
|
|
| +5V |
| +12V [2] | ||
|
|
|
|
|
|
|
|
|
|
|
|
|
Regulation |
|
|
|
|
|
| [5] | ±5% |
|
| ±5% [2] |
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
| [1] [6] | 0.60 |
|
| 0.50 |
|
Avg idle current DCX |
|
|
|
|
| |||||||
Maximum starting current |
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
| ||||||
(peak DC) DC | 3σ | [3] | 0.90 |
|
| 2.00 |
| |||||
(peak AC) AC | 3σ | [3] | 1.10 |
|
| 3.50 |
| |||||
| 3σ |
|
|
|
|
|
| |||||
Delayed motor start (max) DC | [1] [4] | 0.60 |
|
| 0.17 |
| ||||||
Peak operating current: |
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
| ||||||
|
|
|
| [1] | 0.62 |
|
| 0.78 |
| |||
Typical DCX |
|
|
|
|
| |||||||
Maximum DC | 3σ | [1] | 0.74 |
|
| 0.82 |
| |||||
Maximum (peak) DC | 3σ |
| 1.15 |
|
| 1.75 |
| |||||
|
|
|
|
|
|
|
| |||||
Table 4: | ST3500620SS DC power requirements |
|
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
| 3 Gbit mode |
|
| ||
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
| Notes | (Amps) |
|
| (Amps) | |
|
|
|
|
|
|
|
|
|
|
|
| |
Voltage |
|
|
|
|
|
|
| +5V |
|
| +12V [2] | |
|
|
|
|
|
|
|
|
|
|
|
|
|
Regulation |
|
|
|
|
|
| [5] | ±5% |
|
| ±5% [2] |
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
| [1] [6] | 0.60 |
|
| 0.50 |
|
Avg idle current DCX |
|
|
|
|
| |||||||
Maximum starting current |
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
| ||||||
(peak DC) DC | 3σ | [3] | 0.90 |
|
| 2.00 |
| |||||
(peak AC) AC | 3σ | [3] | 1.10 |
|
| 3.50 |
| |||||
| 3σ |
|
|
|
|
|
| |||||
Delayed motor start (max) DC | [1] [4] | 0.60 |
|
| 0.17 |
| ||||||
Peak operating current: |
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
| ||||||
|
|
|
| [1] | 0.62 |
|
| 0.78 |
| |||
Typical DCX |
|
|
|
|
| |||||||
Maximum DC | 3σ | [1] | 0.74 |
|
| 0.82 |
| |||||
Maximum (peak) DC | 3σ |
| 1.15 |
|
| 1.75 |
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
[1]Measured with average reading DC ammeter or equivalent sampling scope. Instantaneous +12V current peaks will exceed these values. Power supply at nominal voltage. N (number of drives tested) = 6, 35 Degrees C ambient.
[2]For +12 V, a
[3]See +12V current profile in Figure 2.
24 | Barracuda ES.2 SAS Product Manual, Rev. G |