Barracuda 7200.7 Serial ATA Product Manual, Rev. N 9
2.8.1.1 Typical current profiles
Figure 1. Typical 5V startup and operation current profile
Figure 2. Typical 12V startup and operation current profile
2.8.2 Deferred spinup
Barracuda 7200.7 Serial ATA drives provide a deferred spinup feature which storage subsystem controllers
can use to sequence disc drive initialization. This is beneficial to systems which include multiple S erial ATA
hard disc drives because it allows subsystem controllers to stagger the spinup of each drive to accomm odate
available power supply current. This feature does not impact time-to-ready in typical desktop systems.
To accommodate the deferred spinup of multiple disc drives in an enclosure, Barracuda 7200.7 Ser ial ATA disc
drives will spin up only after power is applied to th e drive and a fter successfu l PHY (Physi cal layer ) initializa-
tion. PHY initialization occurs after the PHY enters the DP7:DR_Ready state. This state is reached after a suc-
0.0 2 4 6 8 10 12 14 16
0.0
0.25
0.50
0.75
1.00
1.25
A
mps
Seconds
1.50
18
+5 Volt Current during spindle start — Typical Amperes
0.0 2 4 6 8 10 12 14 16
0.0
0.4
0.8
1.2
1.6
2.0
A
mps
Seconds
+12 Volt Current during spindle start — Typical Amperes
2.4
1
8