2.11 Electromagnetic immunity

When properly installed in a representative host system, the drive ope rates without errors or degrad ation in

performance when subjected to the radio frequency (RF) environments defined in the following table:

2.12 Reliability

Table 7: Radio frequency environments

Test Description Performance level Reference standard
Electrostatic discharge Contact, HCP, VCP: ± 4 kV; Air: ± 8 kV B EN 61000-4-2: 95
Radiated RF immunity 80 to 1,000 MHz, 3 V/m,
80% AM with 1 kHz sine
900 MHz, 3 V/m, 50% pulse modulation @
200 Hz
A EN 61000-4-3: 96
ENV 50204: 95
Electrical fast transient ± 1 kV on AC mains, ± 0.5 kV on external I/
OB EN 61000-4-4: 95
Surge immunity ± 1 kV differential, ± 2 kV common, AC
mains B EN 61000-4-5: 95
Conducted RF immunity 150 kHz to 80 MHz, 3 Vrms, 80% AM with
1 kHz sine A EN 61000-4-6: 97
Voltage dips, interrupts 0% open, 5 seconds
0% short, 5 seconds
40%, 0.10 seconds
70%, 0.01 seconds
C
C
C
B
EN 61000-4-11: 94
Nonrecoverable read errors 1 per 1014 bits read, max
Mean time between failures (MTBF) 600,000 power-on hours (nominal power, 25°C ambient temperature)
Contact start-stop cycles 50,000 cycles
(at nominal voltage and temperature, with 60 cycles per hour and a 50% duty
cycle)
Service Life 5 years.
Warranty To determine the warranty for a specific drive, use a w eb brows er to ac ce ss the
follwoing web page:
www.seagate.com/support/service/
From this page, click on the “Verify Your Warranty” link. You will be as ked to pro -
vide the drive serial number, mode l n um ber (or p art number) and country of pur-
chase.
The system will diplay the warranty information for your drive.
Preventive maintenance None required.