2.11Electromagnetic immunity

When properly installed in a representative host system, the drive operates without errors or degradation in performance when subjected to the radio frequency (RF) environments defined in the following table:

Table 7:

Radio frequency environments

 

 

 

 

 

 

 

Test

 

Description

Performance level

Reference standard

 

 

 

 

Electrostatic discharge

Contact, HCP, VCP: ± 4 kV; Air: ± 8 kV

B

EN 61000-4-2: 95

 

 

 

 

Radiated RF immunity

80 to 1,000 MHz, 3 V/m,

A

EN 61000-4-3: 96

 

 

80% AM with 1 kHz sine

 

ENV 50204: 95

 

 

900 MHz, 3 V/m, 50% pulse modulation @

 

 

 

 

200 Hz

 

 

 

 

 

 

Electrical fast transient

± 1 kV on AC mains, ± 0.5 kV on external I/

B

EN 61000-4-4: 95

 

 

O

 

 

 

 

 

 

Surge immunity

± 1 kV differential, ± 2 kV common, AC

B

EN 61000-4-5: 95

 

 

mains

 

 

 

 

 

 

Conducted RF immunity

150 kHz to 80 MHz, 3 Vrms, 80% AM with

A

EN 61000-4-6: 97

 

 

1 kHz sine

 

 

 

 

 

 

Voltage dips, interrupts

0% open, 5 seconds

C

EN 61000-4-11: 94

 

 

0% short, 5 seconds

C

 

 

 

40%, 0.10 seconds

C

 

 

 

70%, 0.01 seconds

B

 

 

 

 

 

 

2.12

Reliability

 

 

 

Nonrecoverable read errors

1 per 1014 bits read, max

Mean time between failures (MTBF)

600,000 power-on hours (nominal power, 25°C ambient temperature)

 

 

Contact start-stop cycles

50,000 cycles

 

 

(at nominal voltage and temperature, with 60 cycles per hour and a 50% duty

 

 

cycle)

 

 

Service Life

5 years.

 

 

 

Warranty

 

To determine the warranty for a specific drive, use a web browser to access the

 

 

follwoing web page:

 

 

www.seagate.com/support/service/

 

 

From this page, click on the “Verify Your Warranty” link. You will be asked to pro-

 

 

vide the drive serial number, model number (or part number) and country of pur-

 

 

chase.

 

 

The system will diplay the warranty information for your drive.

 

 

Preventive maintenance

None required.

 

 

 

14

Barracuda 7200.7 Serial ATA Product Manual, Rev. N

Page 22
Image 22
Seagate ST380013AS, ST3120827AS, ST3120026AS, ST380817AS Electromagnetic immunity, Reliability, Radio frequency environments