2.8Environmental specifications
2.8.1Ambient temperature
Ambient temperature is defined as the temperature of the environment immediately surrounding the drive. Actual drive case temperature should not exceed 70°C (158°F) within the operating ambient conditions. Case temperature of the drive operating at 60°C ambient may hit a maximum of 70°C at certain parts of the casing.
Above 1,000 feet (305 meters), the maximum temperature is derated linearly by 1°C every 1000 feet.
Operating | 0° to 60°C (32° to 140°F) | (70°C max case temperature) |
|
|
|
Nonoperating |
| |
|
|
|
2.8.2Temperature gradient
Operating | 20°C per hour (36°F per hour max), without condensation |
|
|
Nonoperating | 30°C per hour (54°F per hour max), without condensation |
|
|
2.8.3Humidity
2.8.3.1Relative humidity
Operating | 5% to 90% noncondensing (30% per hour max) |
|
|
Nonoperating | 5% to 95% noncondensing (30% per hour max) |
|
|
2.8.3.2Wet bulb temperature
Operating | 33°C | (91.4°F max) [1] |
|
|
|
Nonoperating | 40°C | (104°F max) [2] |
|
|
|
[1]Operating: Wet bulb temperature is calculated by the operating Temperature and the Relative Humidity levels.
[2]Nonoperating: Wet bulb temperature is calculated by the nonoperating Temperature and the Relative Humidity levels.
2.8.4Altitude
Operating | |
|
|
Nonoperating | |
|
|
ST1.3 Series Product Manual, Rev. C | 11 |