Word | ATA specification | Value | |
|
|
| |
59 | Number of sectors transferred during a Read Multiple or Write Multiple command | 0100H | |
Total number of | capacity xxxxH | ||
(see Section 2.2 for related information) | |||
|
| ||
|
|
| |
62 | Retired | 0000H | |
63 | Multiword DMA active and modes supported (see note following this table) | xx07H | |
64 | Advanced PIO modes supported (modes 3 and 4 supported) | 0003H | |
65 | Minimum multiword DMA transfer cycle time per word (120 nsec) | 0078H | |
66 | Recommended multiword DMA transfer cycle time per word (120 nsec) | 0078H | |
67 | Minimum PIO cycle time without IORDY flow control (240 nsec) | 00F0H | |
68 | Minimum PIO cycle time with IORDY flow control (120 nsec) | 0078H | |
0000H | |||
75 | Queue depth | 0000H | |
0000H | |||
80 | Major version number | 00F0H | |
81 | Minor version number | 0000H | |
82 | Command sets supported | 746BH | |
83 | Command sets supported | 5109H | |
84 | Command sets supported extension | 4000H | |
85 | Command sets enabled | 7469H | |
86 | Command sets enabled | 1009H | |
87 | Command sets enabled extension | 4000H | |
88 | Ultra DMA support and current mode (see note following this table) | xx1FH | |
89 | Security erase time | 0000H | |
90 | Enhanced security erase time | 0000H | |
91 | Advanced power management value | 4040H | |
92 | Master password revision code | 0000H | |
93 | Hardware reset value | 400DH | |
94 | Auto acoustic management setting | 8080H | |
0000H | |||
Total number of | 0000H | ||
|
| ||
|
|
| |
0000H | |||
128 | Security status | 0001H | |
xxxxH | |||
0000H | |||
255 | Integrity word | xxA5H |
ST1.3 Series Product Manual, Rev. C | 29 |