2.8.5Shock

All shock measurements in this section are carried out at drive level. For all linear shock test, operating or non- operating, the input shock level shall be measured at the frame of the disk drive at the specific location indi- cated by the ellipse in Figure 5 below for the ZIF interface drives.

Figure 5. Location where tri-axial accelerometer will be placed on ST1.3 Series drives

All shock test will cover all the 6 directions, +/- x, y and z axes. The drive axis definition in shown in Figure 6 below.

Figure 6. Drive axis definition for ST1.3 Series drives

2.8.5.1Operating shock

The drive will be subjected to 10 shocks for each direction. During the shocks, there must be a minimum delay of 3 seconds between shock pulses. Soft errors and automatic retries are allowed during the test. No data loss or permanent damage occurs during a half sine shock pulse of:

300 Gs, 1 msec

2.8.5.2Nonoperating shock

The nonoperating shock level that the drive can experience without incurring any physical damage when sub- sequently put into operation is 2000 Gs. The same applies for shock levels of 2000 Gs, 1 msec pulse duration on fresh drives for each level.

2.8.6Vibration

All vibration specifications assume that the drive is mounted securely in a fixture that does not have fixture resonances in the frequency test range.