b.
HDA Temp.
Check Point
Figure 10. Locations of the HDA temperature check point
6.4.2Relative humidity
The values below assume that no condensation on the drive occurs.
a.Operating
5% to 95%
b.
5% to 95%
6.4.3Effective altitude (sea level)
a.Operating
b.
6.4.4Shock and vibration
Shock and vibration limits specified in this document are measured directly on the drive chassis. If the drive is installed in an enclosure to which the stated shock and/or vibration criteria is applied, resonances may occur internally to the enclosure resulting in drive movement in excess of the stated limits. If this situation is apparent, it may be necessary to modify the enclosure to minimize drive movement.
The limits of shock and vibration defined within this document are specified with the drive mounted by any of the four methods shown in Figure 11, and in accordance with the restrictions of Section 8.3.
6.4.4.1Shock
a.
The drive, as installed for normal operation, shall operate error free while subjected to intermittent shock not exceeding 15 Gs at a maximum duration of 11 msec (half sinewave). The drive, as installed for normal operation, shall operate error free while subjected to intermittent shock not exceeding 20 Gs at a maximum duration of 2 msec (half sinewave). Shock may be applied in the X, Y, or Z axis.
b.
Equipment, as installed for normal operation, does not incur physical damage while subjected to intermit- tent shock not exceeding 40 Gs at a maximum duration of 11 msec (half sinewave). Shock occurring at
Savvio 15K.1 FC Product Manual, Rev. B | 31 |