ATAPI InterfaceChapter 5

Mode Tape Parameters Page

Byte

Description

Value

Meaning

 

 

 

 

0

Page Code

2Bh

Tape Parameters Page

 

 

 

 

1

Page Length

0Eh

14 Bytes of Information

 

 

 

 

2

Density in Kilo bits per inch

NN

Density can imply tape format

 

 

 

 

3

Reserved

00h

 

 

 

 

4

Reserved (Format Fill Byte)

00h

Not used, MFM mode is read only

 

 

 

 

5

BSEG

20h

Number of Blocks per Segment (32)

 

 

 

 

6,7

SEGTRK

NNNN

Number of Segments per Track

 

 

 

 

8,9

TRKS

NN

Number of Tracks (per Tape)

 

 

 

 

10

MAXSECT

80h

Max MFM Sector Value (128)

 

 

 

 

11

MAXCYL

NN

Max MFM Cylinder Value

 

 

 

 

12

MAXHD

NN

Max MFM Head Value

 

 

 

 

13,14

Reserved

0000h

 

 

 

 

15

WDAM,RM,FW (bits 7-5)

00h

Not Used, MFM mode is read only

 

 

 

 

This page is used for MFM (Modified Frequency Modulation), or floppy interface tape formats, such as 2080, 2120, TR1, TR2, TR3, etc. The STT8000A supports the reading of MFM tapes, but does not support write or format operations on MFM tapes.

The following fields are changeable: SEGTRK, TRKS, MAXCYL, and MAXHD.

STT8000A Product Manual

Page 51

Page 59
Image 59
Seagate STT8000A manual Mode Tape Parameters