Sears 139.53535SRT1 Electrical Requirements, if permanent wiring is required by your local

Models: 139.53535SRT1

1 40
Download 40 pages 4.71 Kb
Page 20
Image 20
Electrical Requirements

installation Step 9

Electrical Requirements

To reduce the risk of electric shock, your garage door opener has a grounding type plug with a third grounding pin. This plug will onlyfit into a grounding type outlet.

If the plug doesn't fit into the outlet you have,

contact a qualified electrician to install the proper outlet.

To avoid installation difficulties, do not run the opener at this time.

To prevent electrocution or fire, installation

and wiring must be in compliance with local electrical and building codes.

Do NOT use an extension cord, 2-wire adapter, or change the plug in any way to make it fit your outlet.

RightWrong

if permanent wiring is required by your local

To make a permanent connection through the 7/8" diameter hole in the top of the opener (according to local code):

*Remove the opener cover screws and set the cover aside.

*Remove the attached 3-prong cord.

*Connect the black (line) wire to the screw on the brass terminal; the white (neutral) wire to the screw on the silver terminal; and the ground wire to the green ground screw. The opener must be grounded.

*Reinstall the cover.

code, refer to the following procedure:

Permanent

Wiring

Connections

Ground Tab

Green

Ground

Screw

Ground

Btack

Wire

_ Wire

WhiteWire

Wire

To avoid installation difficulties, do not run the opener at this time.

2O

Page 20
Image 20