installation Step 10 | I |
install the Safety Reversing Sensor
Figures 2 and 3 show assembly of brackets and "C" wrap based on the recommended installation of the sensors as shown on page 21.
However, Figures 4 and 5 are variations which may fit your installation requirements better. Make sure the wraps and brackets are aligned so the sensors will face each other across the garage door.
,Fasten the "C" wraps to the mounting brackets having square holes, using the hardware shown in Figure 2.
•Connect each assembly to a slotted bracket, using the hardware shown in Figure 3.
Note the alignment of the brackets for left and right sides of the door.
•Finger tighten the lock nuts.
•Use bracket mounting holes as a template to locate and drill (2) 3/16" diameter pilot holes on both sides of the garage door,
•Attach bracket assemblies with
•Adjust right and left side bracket assemblies to the same distance out from the mounting surface. Make sure all door hardware obstructions are cleared. Tighten the nuts securely.
Hardware Shown
©
Screw | Lock Nut | Lag Screw |
Figure 4
Alternate Wall Mount
Inside
Garage
Wall
Mounting | Bracket |
|
with | Slot |
|
_ | Mounting | Bracket |
| with Square Holes | |
| with | wire |
| indicator | Light |
Figure 2
Mounting Bracket
With Square | Holes |
.J | "C" Wrap |
i/,
ii
Figure 3
J
| j | Bracket | "C" Wrap |
| with | Slot |
|
/ | _ | M.ounting | Bracket |
_uare |
| Holes | |
| _OCKNuts |
|
|
Actual Size
©
| ||
Staples | Carriage Bolts | Lock Nut |
Figure 5
Alternate Floor Mount
Inside
Garage Sensor with wire
T Wall
, /Indicat°r Light Mounting Bracket with Square Holes
Mounting Bracket j with Stot
Attach with concrete anchors (not provided)
Garage
Floor........
22