Sears Clothes Dryer Prong wimgreen terminals, External terminalblockscrew Neutral wire

Models: Clothes Dryer

1 20
Download 20 pages 49.11 Kb
Page 7
Image 7

Localcodesmaypermittheuseofa U.L.-listed, 120/240-voltminimum,30ampere,dryerpowersupply cordkit(pigtail)PowersupplycordshouldbetypeSRD. orSRDTandbeat leastfourfeetlong.Thewiresthat connecttothedryermustendwithringterminalsor spadeterminalswithturnedends.

Four-Wire Power Supply Cord

(Mobile home or other four-wire installations)

For mobile homes or other four-wire installations, the power supply cord must have four, No.-10 copper wires and match a four-wire receptacle of N EMA Type 14-30R. The fourth wire (grounding conductor) must be identified with a green cover or bare copper wire and the neutral conductor by a white cover.

NEUTRALNEUTRAL

_", U.L.-li_ed, (whi_)

strain relief

nr_nnain.

,s'

prong wim(green) terminals

Four-wErereceptacle

(NEMA Type14-30R)

4.Remove the center terminal block screw. Remove the neutral grounding wire (green/yellow wire) from external grounding screw.

External ground

Center silver-colored

connector,

terminal blockscrew

/

Green/yeNow wire

of harooss

5.Connect neutral grounding wire and the neutral wire

(white) of power supply cord under the center screw of terminal block.

6.Connect the other two insulated wires to outer terminal block screws.

7.Connect the green, grounding wire from the power supply cord to the external grounding conductor screw. Tighten all terminal block screws firmly.

8.Tighten the strain relief screws.

9.Insert tab of terminal block cover into slot of the dryer rear panel. Secure cover with hold-down screw.

Center silver-colored

External terminalblockscrew Neutral wire

ground(white) connector

Do not use an extension cord with this dryer.

Do not connect plug end of power supply cord into a live

receptacle before connecting power supply cord to dryer terminal block.

1.Disconnect power.

2.Remove hold-down screw and terminal block cover.

3.Attach a ¾-inch, U.L.-listed, strain relief to the hole below terminal block opening. Strain relief should have a tight fit with dryer cabinet and be in a horizontal position. Put the power supply cord through the strain relief.

Terminal blockcover

Hold-downscrew

Greenwire/;'_

ofpowersupply I

cordorbare_._ copperwire

%_ Neutral ground- ing wire (green_ellow)

_", U.L-listed, strain relief

7

Page 7
Image 7
Sears Clothes Dryer owner manual Prong wimgreen terminals, External terminalblockscrew Neutral wire