Senatek LS100 manual 3 ‘help’ Command, Getting all parameters screen

Models: LS100

1 46
Download 46 pages 30.74 Kb
Page 20
Image 20

If group is omitted, get command will show all of the parameter values as shown in Figure 2-14.

> get

--- Status ---

Serial_no.: LS100-0207_test

MAC_address: 00-01-95-77-88-99

F/W_REV.: V1.2.0

Current_IP: 192.168.0.125

--- Admin ---

Username: admin

Password: admin

Devicename: LS100 Device

--- IP ---

IP_mode: dhcp

--- Host ---

Host_mode: tcps

Local_port: 6001

Inactivity_timeout(sec): 300

--- Serial ---

Baudrate: 9600

Data_bits: 8_bits

Parity: None

Stop_bits: 1_bit

Flow_control: None

DTR_option: Always_high

DSR_option: None

Interchar_timeout(ms): 50

>

Figure 2-14 Getting all parameters screen

2.4.3 ‘help’ Command

With ‘help’ command, users can find command usage help in the console screen. Basic command usage is as follows:

help [group] + <CR> where,

if group is omitted, overall help screen will be displayed

if group is specified, ‘set’ command usage of specified group will be displayed.

Figure 2-15 shows help screen when no group is specified while Figure 2-16 shows help screen with

‘ip’ group specified.

> help

set group par1 [par2 ...] + <CR>

-group = 'ip','host','serial' or 'admin'

-par1 ... = configuration parameters. Use * to keep a parameter's value get [group] + <CR>

-group = 'ip','host','serial','admin' or 'status'

-If group is specified, shows settings of the group.

-If group is omitted, shows settings of all groups.

help [group] + <CR>

20

Page 20
Image 20
Senatek LS100 manual 3 ‘help’ Command, Getting all parameters screen