16
From the command prompt screen, users can set, get and save configuration parameter values using
set, get and save command. Users also can exit the console or reboot the device using exit and
reboot command. The usage of the commands can be found using help command. For command
usages description, please refer to section 2.4 Command usage.
2.3.2 Using Remote Console
The LS100 provides remote console feature via telnet as well as serial console so that users can
access the LS100 at remote site for configuration and monitoring purpose. The IP address of the
LS100 must be known before users can access the remote console port. The port number for the
remote console is 23, which is a TCP port number assigned for Telnet.
Only one user can log into the remote console or serial console at a time. If the serial console is
established while a remote console is established, current remote console will be halted and no more
remote console will be established until serial console is finished.
To access remote console of the LS100, please use the step as follows:
1) Run a telnet program or a program that supports telnet functions such as TeraTerm-Pro or
HyperTerminal. The target IP address and the port number should be those of the LS100. If
required, specify the port number as 23. Type the following command in the command line
interface of your computer.
telnet 192.168.1.254
Or run a telnet program with parameters as follows.
Figure 2-8 Telnet program set up example
2) The user has to log into the LS100. Type the user name and password. A factory default
setting of the user name and password are both admin.
3) If the user logged into the LS100 successfully, the same command prompt screen as the one