Putting the receiver into operation

Mounting the receiver into a 19” rack

Do not fit the device feet when mounting the receiver into a 19” rack.

CAUTION!

Risks when rack mounting the receiver!

When installing the device in a closed or multi-rack assembly, please consider that, during operation, the ambient temperature, the mechanical loading and the electrical potentials will be different from those of devices which are not mounted into a rack.

￿Make sure that the ambient temperature within the rack does not exceed the permissible temperature limit specified in the specifications (see page 54).

￿Ensure sufficient ventilation; if necessary, provide additional ventila- tion.

￿Make sure that the mechanical loading of the rack is even.

￿When connecting to the power supply, observe the information indi- cated on the type plate. Avoid circuit overloading. If necessary, provide overcurrent protection.

￿When rack mounting, please note that intrinsically harmless leakage currents of the individual mains units may accumulate, thereby exceeding the allowable limit value. As a remedy, ground the rack via an additional ground connection.

Rack mounting

￿ Secure the rack mount “ears”  of the supplied GA 3 rack adapter to

one receiver

the receiver as described on page 12.

 

￿ Secure the blanking plate of the supplied GA 3 rack adapter to one

 

of the rack mount “ears”  using two recessed head screws (M 6x10).

14