Cleaning the transmitter
| Cleaning the transmitter |
|
|
CAUTION! | Liquids can damage the electronics of the transmitter! |
| Liquids entering the housing of the device can cause a |
| electronics. |
| Keep all liquids away from the transmitter. |
|
|
| Before cleaning, disconnect the device from the mains. |
| Use a slightly damp cloth to clean the device from time to time. Do not use any solvents |
| or cleansing agents. |
If a problem occurs ...
Problem | Possible cause | Possible solution |
Transmitter cannot be | Lock mode is activated | Deactivate the lock mode |
operated, “Locked” |
| (see page 18 and page 20). |
appears on the display |
|
|
panel |
|
|
No operation indication | No mains connection | Check the connections of the mains unit. |
No RF signal at the | Transmitter and receiver are not on the | Set the transmitter and receiver to the same |
receiver | same channel | channel. To do so, use the synchronization |
|
| function (see page 14). |
| If “RF Mute” additionally appears on the | Activate the RF signal (see page 18). |
| transmitter display: |
|
| RF signal is deactivated |
|
Very weak RF signal at | Transmission range is exceeded | Check the squelch threshold setting on the |
the receiver |
| receiver. |
|
| Reduce the distance between receiver and |
|
| transmitter. |
|
| Increase the transmission power (see page 20). |
| Receiver’s squelch threshold is adjusted | Reduce the squelch threshold |
| too high | (see the instruction manual of the receiver). |
|
| Reposition the antennas. |
RF signal available, | No input signal at the transmitter | Check the audio level on the transmitter display |
no audio signal at the |
| (see page 7). |
receiver | Very low input signal | Check the audio level on the transmitter |
| ||
|
| display (see page 7), increase the level of |
|
| the input signal or adjust the input sensitivity |
|
| |
Audio signal has a high | Transmitter sensitivity is adjusted too | Adjust the transmitter sensitivity correctly. |
level of background noise | low |
|
|
|
|
23