MAINTENANCE
CENTER & WING GEARBOXES
.The Gearboxes have been filled with lubricant to the proper Level prior to shipment. However, you should check the oil level on dipstick before operating, and frequently thereafter.
The gearbox should not require additional lubricant unless the box is cracked or a seal is leaking. It is recommended that the oil level dipstick be removed after every 8 to 10 hours of operation and oil added until it is at proper level on dipstick. Filler Plugs are located on top of all Gearboxes. Use Rhino Special Gearbox Lube (P/N 00786250)) with a capacity is 6- 1/2 quarts. FIGURE
DIVIDER GEARBOX
The Breather with Dipstick for the Divider Gearbox is located on the right side of the input shaft. The filler pressure relief Plug is on top of the Gearbox.
FIGURE MntP-R-0149
Do not
filled above full mark on Dipstick, pressure under working conditions may cause the Grease Seals to leak.
Use Rhino Special Gearbox Lube (P/N 00786250). Gearbox capacity is 3 quarts for divider gearbox.
Many of the equipment components are HEAVY (60 lbs. or greater) and Special Lifting Procedures are recommended. Use lifting assistance such as mechanical assistance, two people, or proper lifting techniques when handling, removing or installing components to reduce the possibility of back injuries.