HOW TO OPERATE

OFF TIMER OPERATION

This unit has a built-in timer that can be programmed to shut the unit off up to 12 hours in advance.

You can set the timer to stop in increments of 30 minutes (0.5 hours) up to 9.5 hours in advance of the stop time, or in 1 hour increments from 10 to 12 hours in advance of the stop time.

Set the timer when the unit is operating.

The unit will stop automatically according to your setting.

Procedure

 

 

 

 

Pad

 

 

 

Display / Indicator

Touch the TIMER ON/

 

 

 

 

 

 

 

 

 

 

• SELECTOR indicator and

1 OFF pad to set the

 

 

 

TIMER

 

 

 

TIMER indicator will light.

delayed stop time.

 

 

 

ON/OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• If you wish to stop the op-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• The unit is preset to 0.5

 

 

 

 

 

 

 

 

 

 

eration 10 hours later, set

hours (30 minutes).

 

 

 

 

 

 

 

 

 

 

the delay time as shown

 

 

 

 

 

 

 

 

 

 

below.

• The timer will be set, 5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

seconds after the

 

 

 

 

 

 

 

 

 

 

F

TIMER ON/OFF pad is

 

 

 

 

 

 

 

 

 

 

hr

touched for the last

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

time.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• The time setting will change as you touch the pad.

• The time display will count

down the remaining time.

The display will change as follows;

 

 

 

• The unit will stop when the

Preset(0.5h)

 

 

 

 

 

 

 

 

 

 

 

 

 

set time expires.

 

 

 

1.0h

 

 

 

 

 

 

 

• All indicators and displays will

 

0.5h

 

 

1.5h

 

 

10h

 

Previous setting

 

 

 

 

 

 

go out.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CL(cancel)

 

 

12h

 

 

 

11h

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

To cancel the timer setting, touch the TIMER ON/OFF pad again after the timer is set or, press the TIMER ON/OFF pad until CL(cancel) appears on the display.

After setting the OFF TIMER, change the temperature and fan speed settings as shown on pages 11 and 12. When the temperature is set in the timer mode, the temperature will show in the display for 5 seconds and then return to the time display.

The last setting used will be memorized and will appear on the display the next time you operate the unit with the TIMER function.

If a power failure occurs while the ON or OFF TIMER is set, the TIMER memory will be cancelled and will not resume even after power is reinstated. The unit will not automatically start.

OFF TIMER OPERATION can also be set with the REMOTE CONTROL.

15

Page 15
Image 15
Sharp AF-R100CX, AF-R140CX, AF-R120CX operation manual OFF Timer Operation, OFF pad to set, Delayed stop time

AF-R120CX, AF-R140CX, AF-R100CX specifications

The Sharp AF-R140CX, AF-R120CX, and AF-R100CX are part of Sharp's innovative lineup of air conditioning units designed to provide efficient cooling and heating solutions for residential and commercial spaces. These models stand out for their advanced features, energy-efficient technologies, and user-friendly design, making them ideal choices for maintaining a comfortable indoor climate.

One of the key characteristics of the AF-R series is its powerful cooling and heating capabilities. With cooling capacities range from 10,000 to 14,000 BTU/h, these units can effectively manage temperatures in medium to large spaces. The AF-R140CX, being the most robust of the trio, delivers exceptional performance, while the AF-R120CX and AF-R100CX offer slightly reduced capacities suitable for smaller areas.

All models in this series incorporate Sharp’s innovative Plasmacluster Technology, which not only cools or heats the air but also purifies it. This technology releases ions that help to neutralize harmful airborne particles, including allergens, bacteria, and mold, ensuring that the air in your home is not just comfortable but also healthy.

Energy efficiency is another hallmark of the Sharp AF-R series. Each model is equipped with an inverter compressor that automatically adjusts the cooling or heating output based on the room’s requirements. This feature not only helps maintain a consistent temperature but also significantly reduces energy consumption, resulting in lower electricity bills.

User convenience is prioritized in the design of these air conditioning units. They come with a remote control, allowing for easy operation from anywhere in the room. Some models also feature a programmable timer that enables users to set specific cooling or heating schedules, enhancing both comfort and energy savings.

Furthermore, the AF-R series is designed with a sleek, modern aesthetic that fits seamlessly into any interior decor. Their compact size makes installation straightforward, and the units operate quietly, contributing to a peaceful environment.

Overall, the Sharp AF-R140CX, AF-R120CX, and AF-R100CX models exemplify the fusion of style, efficiency, and advanced technology, making them top contenders in the air conditioning market. Users can expect reliable performance, clean air, and significant energy savings, ensuring a comfortable living or working environment year-round.