3

To enter the toner save mode, press the

 

light ( ) key. The light and dark

 

indicator marked "1" will light up,

 

indicating the toner save mode is

 

selected.

4

Press the exposure mode selector key. The PHOTO ( ) indicator

 

will stop blinking and light up steadily. The light and dark indicator

marked "3" will light up. The toner save mode is now active.

To return to the standard mode, repeat the procedure but use the dark () key to select exposure level "5" in step 3.

USER PROGRAMS

The user programs allow the parameters of certain functions to be set, changed, or canceled as desired.

Setting the user programs

1

2

3

Press and hold down the light () key simultaneously for more than 5 seconds until all the alarm indicators ( , , )

blink and " " appears in the display.

Use the left copy quantity ( ) key to select a user program

6

number (For the user program numbers, see the following table.).

The selected number will blink in the left side of the display.

 

Press the start () key. The entered program number will be steadily lit and the currently selected parameter number for the program will blink on the right side of the display.

4 Select the desired parameter using the right copy quantity () key. The entered parameter number will blink on the right of the display.

Program

Mode

 

Parameters

 

No.

 

 

 

 

 

 

 

1

Auto clear time

1

10 sec., 2

30 sec., *3

60 sec.,

4

90 sec., 5

120 sec., 6

OFF

 

 

 

 

 

 

 

 

 

 

*1

30 sec., 2

60 sec., 3

5 min.,

2

Preheat mode

4

30 min., 5

60 min., 6

120 min.,

 

 

7

240 min.

 

 

 

 

 

 

 

 

3

Auto power shut- off

*1

ON, 2 OFF

 

mode

 

 

 

 

 

 

 

 

 

 

 

 

4

Auto power shut- off

*1

5 min., 2

30min., 3

60 min.,

timer

4

120 min., 5

240 min.

 

 

 

 

 

 

 

 

 

55