IF AN ORIGINAL MISFEED OCCURS WHILE USING THE SPF

If a misfeed occurs in the machine when the SPF is used, the SPF will automatically stop scanning. Manually remove the misfed original. You can check the number of originals that must be returned to the document feeder tray in the display on the operation panel. Follow the steps below to display the number of originals to be returned.

The following procedure omits removal of the misfeed. Be sure to remove the misfeed before displaying the number of originals to be returned. For the misfeed removal procedure, see "MISFEED REMOVAL" (p.63).

1 When an original misfeed occurs, the SPF stops and the ZOOM indicator blinks.

The remaining number of sets will blink in the display.

2

3

Remove any originals that have not yet been scanned from the document feeder tray.

Press the copy ratio display (%) key.

The originals that were being scanned in the SPF will be discharged and the number of original sheets to be returned will blink in the display.

Place the displayed number of original sheets back in the document feeder tray together with the original sheets removed in step 2.

Display of number of original sheets to be returned

If "SPF automatic original discharge time" is enabled in the user programs, the originals in the SPF will be automatically discharged after the set time elapses. ("USER PROGRAMS" (p.55))

68