Sharp MX-2614N, MX-3114N, MX-2314N installation manual Press EXECUTE key

Models: MX-2314N MX-3114N MX-2614N

1 19
Download 19 pages 2.35 Kb
Page 12
Image 12
2)Press [EXECUTE] key.

2)Press [EXECUTE] key.

[EXECUTE] key is highlighted and the image registration auto- matic adjustment is started. (It takes about 15 sec to complete the adjustment.)

3)When the adjustment is completed, [EXECUTE] key returns to the normal display, and the value of the adjustment result is displayed.

The current skew level for each color is displayed on the SKEW display section.

Display/

 

 

Content

Display

Default

NOTE

Item

 

 

 

 

 

 

 

 

MAIN F

C

Registration adjustment value main scanning

1.0 - 199.0

100

 

 

 

direction (Cyan laser writing position F side)

 

 

 

 

M

Registration adjustment value main scanning

1.0 - 199.0

100

 

 

 

direction (Magenta laser writing position F side)

 

 

 

 

Y

Registration adjustment value main scanning

1.0 - 199.0

100

 

 

 

direction (Yellow laser writing position F side)

 

 

 

MAIN R

C

Registration adjustment value main scanning

1.0 - 199.0

100

 

 

 

direction (Cyan laser writing position R side)

 

 

 

 

M

Registration adjustment value main scanning

1.0 - 199.0

100

 

 

 

direction (Magenta laser writing position R side)

 

 

 

 

Y

Registration adjustment value main scanning

1.0 - 199.0

100

 

 

 

direction (Yellow laser writing position R side)

 

 

 

SUB

C

Registration adjustment value sub scanning direction

1.0 - 199.0

100

 

 

 

(Cyan drum

Black drum)

 

 

 

 

M

Registration adjustment value sub scanning direction

1.0 - 199.0

100

 

 

 

(Magenta drum

Black drum)

 

 

 

 

Y

Registration adjustment value sub scanning direction

1.0 - 199.0

100

 

 

 

(Yellow drum

Black drum)

 

 

 

SKEW

C

Print skew amount calculation result (Cyan)

-99.9 - 99.9

0

If the value is positive (+), "L" is displayed at the head of the

 

M

Print skew amount calculation result (Magenta)

-99.9 - 99.9

0

value. If negative (–), "R" is displayed.

 

Y

Print skew amount calculation result (Yellow)

-99.9 - 99.9

0

If the value is in the range of –2.1 - +2.1, "(OK)" is displayed at

 

 

 

 

 

 

 

 

the bottom of the value. In the other cases, "(NG)" is displayed.

ALL_

Print skew amount calculation result (Overall)

-99.9 - 99.9

0

If the value is positive (+), "L" is displayed at the head of the

ROTATE

 

 

 

 

 

value. If negative (–), "R" is displayed.

 

 

 

 

 

 

If the value is in the range of –1.6 - +1.6, "(OK)" is displayed at

 

 

 

 

 

 

the bottom of the value. In the other cases, "(NG)" is displayed.

PHASE

OPC drum phase adjustment value

1 - 8

1

 

4)Write down the displayed skew level.

(Meaning of the skew level value and the adjustment proce- dure)

* If "OK" is displayed for all items of SKEW ALL_ROTATE, C, M, and Y, there is no need to perform the adjustment.

*When "R" is displayed at the head of the value, turn the LSU skew adjustment screw clockwise.

*When "L" is displayed at the head of the value, turn the LSU skew adjustment screw counterclockwise.

*The turning amount of the adjustment screw corresponds to each adjustment value. "ALL_ROTATE" indicates the num- ber of rotations, and C, M, and Y indicate numbers of clicks. The display value is rounded at the decimal point.

*"ALL_ROTATES" shows the number of rotations of adjust- ments for all the adjustment screws. "C, M, and Y(SKEW)" shows the number of adjustment click steps for each adjust- ment screw of C, M, and Y.

Contents in ( )

MIAN, SUB: Difference from the previous adjustment value of image registration.

Example:

If 105 for this time and 103 for the previous time, it is displayed as 105.0 (+2.0).

SKEW, ALL_ROTATE: Judgment of the LSU skew adjustment result. OK or NG.

PHASE: OPC drum phase adjustment value of the previous time

MX-3114N MX-2314N/2614N/3114N (MAIN UNIT) 2 – 8

Page 12
Image 12