Controlling the Monitor with a PC (Continued)

RS-232C command table

<How to read the command table>

Command:

Command field (See page 37.)

Direction:

W

When the “Parameter” is set in the parameter field (see page 37), the

 

 

command functions as described under “Control/Response Contents”.

 

R

The returned value indicated under “Reply” can be obtained by setting

 

 

“????”, “

 

 

 

 

 

 

 

 

 

 

 

?” or “???+” (repeater control) in the parameter field (see

 

 

 

 

 

 

 

 

 

 

page 37).

 

 

 

 

 

 

 

 

 

Parameter:

Parameter field (See page 37.)

Reply:

Response (Returned value)

* “Yes” indicates commands which can be used in power standby mode.

TIPS

• To specify the horizontal/vertical positions for vertical orientation, specify the values for horizontal orientation.

Power control/Input mode selection

 

 

 

 

 

 

Can be used

Control item

Command

Direction

Parameter

Reply

Control/Response contents

in standby

 

 

 

 

 

 

mode

POWER CONTROL

POWR

W

0

 

Switches to standby mode.

 

 

 

 

 

 

 

 

 

 

 

1

 

Returns from standby mode.

 

 

 

 

 

 

 

 

 

 

R

 

0

Standby mode

Yes

 

 

 

 

 

 

 

 

 

 

 

1

Normal mode

 

 

 

 

 

 

 

 

 

 

 

 

2

Input signal waiting mode

 

 

 

 

 

 

 

 

INPUT MODE SELECTION

INPS

W

0

 

Toggle change for input mode

 

 

 

 

 

 

 

 

 

 

 

1

 

PC digital RGB (DVI) (DIGITAL)

 

 

 

 

 

 

 

 

 

 

 

2

 

PC analog RGB (ANALOG)

 

 

 

 

 

 

 

 

 

 

 

3

 

Component (COMPONENT)

 

 

 

 

 

 

 

 

 

 

 

4

 

Video (S-Video • Video)

Yes

 

 

 

 

 

 

 

 

 

R

 

1

PC digital RGB (DVI) (DIGITAL)

 

 

 

 

 

 

 

 

 

 

 

 

2

PC analog RGB (ANALOG)

 

 

 

 

 

 

 

 

 

 

 

 

3

Component (COMPONENT)

 

 

 

 

 

 

 

 

 

 

 

 

4

Video (S-Video • Video)

 

 

 

 

 

 

 

 

E44