Controlling the Monitor with a PC

Initialisation/Functional Restriction Setting (FUNCTION) menu

Functio

Command

Direction

Parameter

 

Reply

 

Control/Response contents

ALL RESET

RSET

W

 

0

 

 

 

ADJUSTMENT LOCK

ALCK

WR

 

0-2

 

0-2

0: OFF

OSD DISPLAY

LOSD

WR

 

0-1

 

0-1

0: ON, 1: OFF

LED

OFLD

WR

 

0-1

 

0-1

0: ON, 1: OFF

 

 

 

 

 

 

 

 

*

No

Yes

Yes

Yes

Others

Function

Command

Direction

Parameter

Reply

Control/Response contents

*

SCREEN SIZE (PC)

 

WIDE

WR

1-5

1-5

1: WIDE, 2: NORMAL, 3: DotbyDot, 4: ZOOM1, 5: ZOOM2

Yes

 

 

 

 

 

 

 

 

 

SCREEN SIZE (AV)

 

WIDE

WR

1-5

1-5

1: WIDE, 2: ZOOM1, 3: ZOOM2, 4: NORMAL, 5: DotbyDot

Yes

 

 

 

 

 

 

 

 

 

VOLUME

 

VOLM

WR

0-31

0-31

 

Yes

 

 

 

 

 

 

 

 

 

MUTE

 

MUTE

WR

0-1

0-1

0: OFF, 1: ON

No

 

 

 

 

 

 

 

 

 

INFORMATION

 

MODEL

INF1

R

 

Value

 

Yes

 

 

 

 

 

 

 

 

 

 

SERIAL NO

SRNO

R

 

Value

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BRIGHT

 

VLMP

WR

0-31

0-31

Brightness

Yes

 

 

 

 

 

 

 

TEMPERATURE SENSOR

DSTA

R

 

0

Internal temperature normal

 

 

 

 

 

 

 

1

Internal temperature abnormal (Standby mode)

 

 

 

 

 

 

 

2

Internal temperature abnormal (Temperature is normal now, but it was

Yes

 

 

 

 

 

 

 

abnormal during operation.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

Internal temperature abnormal (Brightness of the backlight decreases.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

Temperature sensor abnormal

 

 

 

 

 

 

 

 

TEMPERATURE ACQUISITION

ERRT

R

 

Value

Temperature at temperature sensors 1 through 3 are returned in the

 

 

 

 

 

 

 

 

following forms:

Yes

 

 

 

 

 

 

 

[Sensor 1], [Sensor 2], [Sensor 3]

 

CAUSE OF LAST STANDBY MODE

STCA

W

0

 

Initialisation

 

 

 

 

 

R

 

0

No detectable error has occurred

 

 

 

 

 

 

 

1

Standby mode by POWER button

 

 

 

 

 

 

 

2

Main power “OFF” by the main power switch

Yes

 

 

 

 

 

 

3

Standby mode by RS-232C

 

 

 

 

 

 

 

 

 

 

 

 

 

4

Waiting mode by No Signal (Incl: VESA DPMS/DMPM)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

Standby mode by abnormal temperature

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

Standby mode by SCHEDULE setting

 

E32

Page 34
Image 34
Sharp PN-465E operation manual Others, Temperature Sensor Dsta