Controlling the Monitor with a PC (RS-232C)
SETUP menu
| Function | Command | Direction | Parameter | Reply | Control/Response contents | * | |
DATE/TIME SETTING | DATE | WR | AABBCCDDEE | AABBCCDDEE | AA: Year, BB: Month, CC: Day, DD: Hour, EE: Minute |
| ||
|
|
|
|
|
|
|
|
|
ID SETTING |
| ID NO.SETTING | IDST | W |
| Sets the monitor’s ID number. (“0” means “no ID number”.) |
| |
|
|
|
| R |
| Returns the monitor’s ID number. |
| |
|
| ID NO. SETTING | IDSL | W |
| Sets a monitor ID number. |
| |
|
| (ONCE) |
|
|
|
| This ID number is only effective for the command immediately after this |
|
|
|
|
|
|
|
| command. |
|
|
|
|
|
| 0 |
| Clears the ID number if one has been designated. |
|
|
| ID NO. SETTING | IDLK | W |
| Sets a monitor ID number. |
| |
|
| (SUBSEQUENT) |
|
|
|
| This ID number is effective for the next and all subsequent commands after this |
|
|
|
|
|
|
|
| command. |
|
|
|
|
|
| 0 |
| Clears the ID number if one has been designated. |
|
|
|
|
|
|
|
|
|
|
MULTI |
| ENLARGE | ENLG | WR | 0: OFF, 1: ON |
| ||
|
| ENLARGE MODE | EMHV | WR | 1 x 1 (OFF) to 5 x 5 (“m x n” is expressed as “mn”, where m and n are the | ○ | ||
|
|
|
|
|
|
| numbers of monitors specified for the longest direction and the shortest direction | |
|
|
|
|
|
|
| respectively.) |
|
|
| IMAGE POSITION | EPHV | WR | Specifies values in the order of IMAGE POSITION IN LONGEST/ SHORTEST |
| ||
|
| (M x N) |
|
|
|
| DIRECTION. |
|
|
| BEZEL ADJUST | BZCO | WR | 0: OFF, 1: ON |
| ||
|
| ENLARGE/ | ESHV | WR | XXYY | XXYY | XX: ENLARGE MODE (Same as EMHV), YY: IMAGE POSITION (Same as |
|
|
| IMAGE POSITION |
|
|
|
| EPHV) |
|
|
| SETTING |
|
|
|
|
|
|
THERMAL SENSOR SETTING | STDR | WR | 0: LANDSCAPE, 1: PORTRAIT |
| ||||
ADJUSTMENT |
| MONITOR | ALCM | WR | 0: UNLOCKED, 1: LOCK ALL, 3: LOCK EXCEPT POWER |
| ||
LOCK |
| BUTTONS |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| REMOTE | ALCR | WR | 0: UNLOCKED, 1: LOCK ALL, 2: LOCK EXCEPT VOLUME, |
| ||
|
| CONTROL |
|
|
|
| 3: LOCK EXCEPT POWER |
|
Others
| Function | Command | Direction | Parameter | Reply | Control/Response contents | * | |
|
|
|
|
|
|
|
|
|
VOLUME |
|
| VOLM | WR |
| ○ | ||
MUTE |
|
| MUTE | WR | 0: OFF, 1: ON | - | ||
INFORMATION |
| MODEL | INF1 | R |
| Value |
|
|
|
| SERIAL NO | SRNO | R |
| Value |
|
|
TEMPERATURE SENSOR | DSTA | R |
| 0 | Internal temperature normal |
| ||
|
|
|
|
|
| 1 | Internal temperature abnormal has occurred and the monitor is in standby mode |
|
|
|
|
|
|
| 2 | Internal temperature abnormal occurred (To delete the information of temperature |
|
|
|
|
|
|
|
| abnormal, turn off the main power.) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 3 | Internal temperature abnormal has occurred and backlight brightness is dimmed |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 4 | Temperature sensor abnormal |
|
|
|
|
|
|
|
| ||
TEMPERATURE ACQUISITION | ERRT | R |
| Value | Returns the temperature at the temperature sensors in the following format. |
| ||
|
|
|
|
|
|
| [Sensor 1] |
|
CAUSE OF LAST STANDBY MODE | STCA | W | 0 |
| Initialization | ○ | ||
|
|
|
| R |
| 0 | No detectable error has occurred | |
|
|
|
|
|
| |||
|
|
|
|
|
| 1 | Standby mode by POWER button |
|
|
|
|
|
|
| 3 | Standby mode by |
|
|
|
|
|
|
| 4 | Input signal waiting mode by No Signal |
|
|
|
|
|
|
| 6 | Standby mode by abnormal temperature |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 8 | Standby mode by SCHEDULE setting |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 20 | Standby mode by OFF IF NO OPERATION setting |
|
|
|
|
|
|
|
|
|
|
LAN SETUP |
| USERNAME | USER | WR | XXXXXXXX | XXXXXXXX | X: Eight characters or less; |
|
|
|
|
|
|
|
| (The field can be left blank, but spaces cannot be entered.) |
|
|
| PASSWORD | PASS | WR | XXXXXXXX | XXXXXXXX | X: Eight characters or less; |
|
|
|
|
|
|
|
| (The field can be left blank, but spaces cannot be entered.) |
|
TIPS
• Some menu setting items do not have a command. Set with the remote control during installation.