Sherwood SRB3600 manual Testing Of Second Stage Inhalation effort, Exhalation Effort, Leak Test

Models: SRB3600

1 29
Download 29 pages 21.59 Kb
Page 21
Image 21

d.Replace the diaphragm. Continue to test the gap between the lever and the diaphragm after each bending until the lever is in the correct position.

10.Return to Section 6.3, Step 13 of this manual (Assembly of Second Stage) to complete assembly of the regulator.

6.5TESTING Of SECOND STAGE

6.5.1Inhalation effort

Check the inhalation effort of the second stage with a pan of water about five inches deep.

1Slowly immerse the second stage with the front cover down and level. The regulator should flow as soon as the diaphragm is a little deeper than level with surface of the water.

2.If you use a water column or water manometer to check inhalation effort, it should not exceed 11/4" w. c. (3.2 cm) at cracking. It should drop to about 3/4" w. c. (19 cm) at one atmosphere

and a moderate flow rate. You can alter the inhalation effort within a certain range.

3.You can increase the inhalation effort by turning the adjusting nut 29 counter-clockwise. However, discontinue counter-clockwise adjusting when the lever 27 becomes loose against the lever support 26 .

4.You can decrease the inhalation effort by turning the adjusting nut clockwise. Discontinue clockwise adjusting when air begins to hiss past the second stage poppet.

6.5.2 Exhalation Effort

1If you do not use instruments to check the exhalation effort, the flow should feel smooth and unrestricted.

2.If you use a water column, it should not exceed 1/2" w.c. (1.3 cm) at one atmosphere.

3.Brand new Exhaust Valves will sometimes adhere slightly to the case, causing a slight increase in inhalation effort. This condition will disappear with use.

6.5.3 Leak Test

1 .

Disconnect the air supply. Purge the regulator of all positive air pressure.

2.Slowly immerse the second stage in a pan of water with the mouthpiece pointing straight up.

3.Immerse the regulator until the water is 1/4" to 1/8" (.64 to .32 cm) from the lip of the mouthpiece.

4.Hold the regulator in this position for one minute and then slowly raise it out of the water.

5.Tip the regulator mouthpiece downward and watch the inside of the mouthpiece tube. If any water escapes from the mouthpiece tube, check for source of leakage.

18

Page 21
Image 21
Sherwood SRB3600 manual Testing Of Second Stage Inhalation effort, Exhalation Effort, Leak Test