AS-Interface

AS-Interface Safety at work

AS-Interface safe compact modules

Schematics

Logical assignments

K45F Safe Compact Module

1

2

 

 

2

 

 

 

3

￿ ￿ ￿ ²

1

3

4

 

 

4

 

 

 

ADDR

 

 

G_NSA0_XX_00355

 

 

 

 

Socket

Assignment / data sheet / function

 

1

Pin 1 and Pin 2: affects bits D0 and D1 = Channel 1

 

 

Pin 3 and Pin 4: affects bits D2 and D3 = Channel 2

 

 

Pin 5 not assigned

 

2

Pin 1 and Pin 2: affects bits D2 and D3 = Channel 2

 

 

Pin 5 not assigned

6

3

Unused

4

Unused

 

 

 

If only one single-channel switch will be connected to the mod- ule, this must be connected to Channel 1. The second channel must be bridged. This can be performed with the M12 connector 3RK1901-1AA00 on Socket 2.

Pin 3 of Socket 1 is connected to Pin 1 of Socket 2 and Pin 4 of Socket 1 is connected to Pin 2 of Socket 2. If both socket pairs are assigned, the inputs are linked.

K60F Safe Compact Module

12

34

56

78

41

3 2 NSA_00358

Socket

Assignment / data sheet / function

1

Pin1 and Pin 2: affects bits D0 and D1 = Channel 1

 

Pin 3 and Pin 4: affects bits D2 and D3 = Channel 2

 

Pin 5: unused

2

Pin 1 and Pin 2: affects bits D2 and D3 = Channel 2

 

Pin 5: unused

3/4/7 and

Not assigned, factory sealed

8

 

5

Pin 4: Output 1

 

Pin 3: --

 

Pin 5: Ground

 

Pin 1 and Pin 2: unused

6

Pin 4: Output 2

 

Pin 3: --

 

Pin 5: Ground

 

Pin 1 and Pin 2: unused

 

 

Pin 3 of Socket 1 is connected to Pin 1 of Socket 2 and Pin 4 of Socket 1 is connected to Pin 2 of Socket 2. If both socket pairs are assigned, the inputs are linked.

6/14

Siemens IK PI · 2004

Page 14
Image 14
Siemens EN 50295 manual Schematics, Logical assignments, K45F Safe Compact Module, K60F Safe Compact Module

EN 50295 specifications

Siemens EN 50295 is emerging as a pivotal standard in the domain of electrical safety and design, particularly relevant for the electrical industry and equipment manufacturing sectors. Primarily, this European Norm is geared towards ensuring the safety of electrical systems used in dry environments, which is essential for various industrial applications.

One of the main features of the EN 50295 standard is its comprehensive safety requirements which are aimed at mitigating the risks associated with electrical systems. This includes aspects like insulation resistance, protective earthing, and the management of electrical faults. By setting a benchmark for safety, Siemens EN 50295 assists manufacturers in maintaining compliance with national and international regulations, thus protecting both users and equipment.

The standard emphasizes the importance of safety measures in the design process. It outlines criteria for components, assembly methods, and system installation, ensuring that electrical equipment operates stably and gets rid of risks related to electrical failures. This involves rigorous testing of materials and components, which enhances their reliability and longevity while providing efficient overall operation.

Siemens EN 50295 also incorporates advancements in technology, acknowledging the significance of intellectual innovation in the industry. It encourages the integration of smart technologies and automation features into electrical systems, paving the way for enhanced operational efficiencies. Such technologies not only improve the performance of electric systems but also contribute to energy conservation, reducing the overall environmental footprint.

Another characteristic of the EN 50295 standard is its adaptability. The framework it provides can be customized depending on specific industry needs, making it versatile across various sectors such as manufacturing, construction, and transportation. This adaptability ensures that businesses can maintain high safety standards while still allowing room for innovation and modern practices.

In summary, Siemens EN 50295 presents a well-rounded approach to enhancing safety, reliability, and sustainability in electrical systems. Its features and characteristics are set to guide industries in making informed decisions regarding electrical configuration, ultimately fostering a safer and more efficient working environment. The incorporation of emerging technologies ensures that the standard remains relevant in a fast-evolving technological landscape, proving to be an invaluable asset for manufacturers and service providers alike.